Skip to main content
VulnerabilityPublished

CVE-2026-24101: Tenda AC15V1.0 · OS Command Injection

Source CVE Database V5

0

Not known to be exploited · CVSS 9.8 Critical.

Data as of 26 Oct 2026, 14:05 UTC

CVSS 3.1 base score
9.8Critical
How severe the flaw is on the 0–10 CVSS scale.
EPSS
1.7% chance of exploitation in 30 days – higher than 78% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 2 Mar 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

AI-suggested

To mitigate CVE-2026-24101, organizations should first check for firmware updates from Tenda addressing this vulnerability and apply them promptly once available. In the absence of an official patch, administrators should restrict access to the router's web management interface by limiting it to trusted internal networks and disabling remote management features. Implement network segmentation to isolate vulnerable devices from critical assets. Change default credentials to strong, unique passwords to prevent unauthorized access. Monitor network traffic for unusual activity indicative of exploitation attempts. Employ web application firewalls or intrusion detection systems capable of detecting command injection patterns targeting the goform/formSetIptv endpoint. If possible, disable IPTV features or the vulnerable endpoint until a fix is applied. Regularly audit router configurations and logs to detect and respond to suspicious behavior. Finally, consider replacing affected devices with models from vendors with a stronger security track record if timely patches are not forthcoming.

Description

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18_multi. When the condition is met, `s1_1` will be passed into sub_B0488, concatenated into `doSystemCmd`. The value of s1_1 is not validated, potentially leading to a command injection vulnerability.

References

Community reviews