Skip to main content
VulnerabilityPublished Updated

CVE-2026-24105: Tenda AC15V1.0 · Code Injection

Source CVE Database V5

0

Not known to be exploited · CVSS 9.8 Critical.

Data as of 26 Oct 2026, 17:16 UTC

CVSS 3.1 base score
9.8Critical
How severe the flaw is on the 0–10 CVSS scale.
EPSS
1.8% chance of exploitation in 30 days – higher than 78% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 2 Mar 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

AI-suggested

  1. Immediately restrict access to the router's management interface by limiting it to trusted internal networks and disabling remote management if not required.
  2. Implement network-level firewall rules to block unauthorized access to the vulnerable endpoint (goform/formsetUsbUnload).
  3. Monitor network traffic and router logs for unusual commands or access patterns indicative of exploitation attempts.
  4. Contact Tenda support or check official channels regularly for firmware updates or patches addressing this vulnerability.
  5. 6. Employ network segmentation to isolate vulnerable devices from critical infrastructure. 7. Use intrusion detection/prevention systems (IDS/IPS) to detect and block command injection attempts targeting this vulnerability. 8. Educate users and administrators about the risks of exposing router management interfaces to the internet.

Description

An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18_multi. The value of `v1` was not checked, potentially leading to a command injection vulnerability if injected into doSystemCmd.