CVE-2026-27662: CWE-1188: Initialization of a Resource with an Insecure Default in Siemens SIMATIC HMI MTP1000 Unified Comfort Panel
Affected devices do not properly restrict access to the web browser via the Control Panel when no corresponding security mechanisms are in place. This could allow an unauthenticated attacker to gain unauthorized access to the web browser, potentially enabling the discovery of backdoors, performing unauthorized actions, or exploiting misconfigurations that may lead to further system compromise.
AI Analysis
Technical Summary
CVE-2026-27662 is a vulnerability in Siemens SIMATIC HMI MTP1000 Unified Comfort Panel where the device does not properly restrict access to its web browser interface via the Control Panel if no security mechanisms are in place. This insecure default initialization (CWE-1188) can allow unauthenticated attackers to gain unauthorized access to the web browser, potentially enabling discovery of backdoors, unauthorized actions, or exploitation of misconfigurations that may lead to further compromise. The vulnerability has a CVSS 3.1 base score of 7.7, indicating high severity, with attack vector local, low attack complexity, no privileges required, no user interaction, unchanged scope, no confidentiality impact, but high integrity and availability impacts. No patch or official remediation level has been published by Siemens at this time.
Potential Impact
An unauthenticated attacker with local access to the device's Control Panel could gain unauthorized access to the embedded web browser. This access may allow the attacker to discover hidden backdoors, perform unauthorized actions, or exploit misconfigurations, potentially leading to significant integrity and availability impacts on the affected system. Confidentiality is not impacted according to the CVSS vector. No known exploits are currently reported in the wild.
Mitigation Recommendations
Patch status is not yet confirmed — check the Siemens vendor advisory for current remediation guidance. Until an official fix is available, ensure that appropriate security mechanisms are configured on the device to restrict access to the Control Panel and web browser interface. Avoid leaving the device in default or insecure configurations that allow unrestricted access.
CVE-2026-27662: CWE-1188: Initialization of a Resource with an Insecure Default in Siemens SIMATIC HMI MTP1000 Unified Comfort Panel
Description
Affected devices do not properly restrict access to the web browser via the Control Panel when no corresponding security mechanisms are in place. This could allow an unauthenticated attacker to gain unauthorized access to the web browser, potentially enabling the discovery of backdoors, performing unauthorized actions, or exploiting misconfigurations that may lead to further system compromise.
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2026-27662 is a vulnerability in Siemens SIMATIC HMI MTP1000 Unified Comfort Panel where the device does not properly restrict access to its web browser interface via the Control Panel if no security mechanisms are in place. This insecure default initialization (CWE-1188) can allow unauthenticated attackers to gain unauthorized access to the web browser, potentially enabling discovery of backdoors, unauthorized actions, or exploitation of misconfigurations that may lead to further compromise. The vulnerability has a CVSS 3.1 base score of 7.7, indicating high severity, with attack vector local, low attack complexity, no privileges required, no user interaction, unchanged scope, no confidentiality impact, but high integrity and availability impacts. No patch or official remediation level has been published by Siemens at this time.
Potential Impact
An unauthenticated attacker with local access to the device's Control Panel could gain unauthorized access to the embedded web browser. This access may allow the attacker to discover hidden backdoors, perform unauthorized actions, or exploit misconfigurations, potentially leading to significant integrity and availability impacts on the affected system. Confidentiality is not impacted according to the CVSS vector. No known exploits are currently reported in the wild.
Mitigation Recommendations
Patch status is not yet confirmed — check the Siemens vendor advisory for current remediation guidance. Until an official fix is available, ensure that appropriate security mechanisms are configured on the device to restrict access to the Control Panel and web browser interface. Avoid leaving the device in default or insecure configurations that allow unrestricted access.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- siemens
- Date Reserved
- 2026-02-23T10:07:00.530Z
- Cvss Version
- 3.1
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a02f11acbff5d8610c13ada
Added to database: 5/12/2026, 9:21:30 AM
Last enriched: 5/12/2026, 9:37:22 AM
Last updated: 5/13/2026, 4:50:53 AM
Views: 8
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.