CVE-2026-28698: CWE-497 Exposure of sensitive system information to an unauthorized control sphere in Pronetiqs Panduit Intravue
Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could expose the underlying host/share filesystem.
AI Analysis
Technical Summary
CVE-2026-28698 describes a vulnerability in Pronetiqs Panduit Intravue (versions 3.2.1a14 and prior) where sensitive system information is exposed to unauthorized control spheres. This exposure may allow attackers to access underlying host or shared filesystem details. The vulnerability is identified as CWE-497, indicating improper exposure of sensitive information. The CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N) indicates that the vulnerability is remotely exploitable without privileges or user interaction, affects confidentiality with a high impact, and has a scope change. No vendor advisory or patch information is provided, and the remediation level is unspecified.
Potential Impact
An attacker can remotely access sensitive system information without authentication or user interaction, potentially gaining detailed knowledge of the underlying host or shared filesystem. This could facilitate further attacks or unauthorized data access. The confidentiality impact is high, but integrity and availability are not affected. No known exploits are reported in the wild at this time.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Since no official fix or mitigation is currently documented, organizations should monitor vendor communications for updates. Until a patch is available, restrict network access to the affected system to trusted sources and apply network-level controls to limit exposure.
CVE-2026-28698: CWE-497 Exposure of sensitive system information to an unauthorized control sphere in Pronetiqs Panduit Intravue
Description
Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could expose the underlying host/share filesystem.
CVSS v3.1
Score 8.6high
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2026-28698 describes a vulnerability in Pronetiqs Panduit Intravue (versions 3.2.1a14 and prior) where sensitive system information is exposed to unauthorized control spheres. This exposure may allow attackers to access underlying host or shared filesystem details. The vulnerability is identified as CWE-497, indicating improper exposure of sensitive information. The CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N) indicates that the vulnerability is remotely exploitable without privileges or user interaction, affects confidentiality with a high impact, and has a scope change. No vendor advisory or patch information is provided, and the remediation level is unspecified.
Potential Impact
An attacker can remotely access sensitive system information without authentication or user interaction, potentially gaining detailed knowledge of the underlying host or shared filesystem. This could facilitate further attacks or unauthorized data access. The confidentiality impact is high, but integrity and availability are not affected. No known exploits are reported in the wild at this time.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Since no official fix or mitigation is currently documented, organizations should monitor vendor communications for updates. Until a patch is available, restrict network access to the affected system to trusted sources and apply network-level controls to limit exposure.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- icscert
- Date Reserved
- 2026-06-15T17:14:43.847Z
- Cvss Version
- 3.1
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a6297b09c2644c7f8d3bb9d
Added to database: 07/23/2026, 22:37:36 UTC
Last enriched: 07/30/2026, 23:05:53 UTC
Last updated: 09/06/2026, 22:52:09 UTC
Views: 80
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.