Skip to main content
VulnerabilityPublished

CVE-2026-38056: ST Engineering iDirect Evolution iQ‑Series terminals · Missing Authorization

Affects ST Engineering iDirect Evolution iQ‑Series terminalsSource CVE Database V5

0

Not known to be exploited · CVSS 8.8 High.

Data as of 26 Oct 2026, 17:16 UTC

CVSS 3.1 base score
8.8High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.1% chance of exploitation in 30 days – higher than 4% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 11 Sep 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

Affected software

ProductAffectedFixed in
ST Engineering iDirectEvolution iQ‑Series terminalsAffected
  • <=4.5.2.1
Fixed in–
ST Engineering iDirect3315-Series terminalsAffected
  • <=4.5.2.1
Fixed in–
ST Engineering iDirect9-Series TerminalsAffected
  • <=4.5.2.1
Fixed in–

AI-suggested

Until an official fix is available, restrict local access to authorized personnel only and monitor for unauthorized physical access. No vendor advisory or patch links are currently provided.

Description

A local privilege escalation vulnerability exists in the iDirect iQ200 VSAT terminal running firmware 23.0.1.0. The iQ200 is a rackmount satellite modem deployed across oil and gas, maritime, defense, and remote infrastructure as the primary, and often sole communications link for offshore rigs, vessels, and remote sites. Important context: the device ships from the factory with a pre-configured low-privilege local user account. This account is intended for field technicians who need shell access for maintenance and diagnostics but should not have full administrative control over the device. This built-in account provides the initial access required to exploit this vulnerability. No additional credentials need to be obtained or brute-forced.

References

Community reviews

Loading reviews…