Skip to main content

CVE-2026-3869: CWE-303 Incorrect implementation of authentication algorithm in Schneider Electric Modicon M580

0
Critical
VulnerabilityCVE-2026-3869cvecve-2026-3869cwe-303
Published: 09/11/2026 (09/11/2026, 15:13:18 UTC)
Source: CVE Database V5
Vendor/Project: Schneider Electric
Product: Modicon M580

Description

CVE-2026-3869 is a critical vulnerability in Schneider Electric Modicon M580 PLCs caused by an incorrect implementation of the authentication algorithm (CWE-303). This flaw may lead to loss of confidentiality, integrity, and availability of the PLC when an application project with a lower application level is running on the device.

CVSS v4.0

Score 9.2critical

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
Present
Privileges Required
None
User Interaction
None
Vuln. Confidentiality
High
Vuln. Integrity
High
Vuln. Availability
High
Subsq. Confidentiality
None
Subsq. Integrity
None
Subsq. Availability
None
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Affected software

Schneider Electric

Modicon M580

Schneider Electric

Modicon M580 Safety

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 09/11/2026, 15:46:51 UTC

Technical Analysis

The vulnerability identified as CVE-2026-3869 involves an incorrect implementation of the authentication algorithm in Schneider Electric Modicon M580 programmable logic controllers. This weakness could allow an attacker to compromise the confidentiality, integrity, and availability of the PLC, specifically when a lower application level project is active on the device. The CVSS 4.0 base score is 9.2, indicating a critical severity with network attack vector, low attack complexity, no privileges required, no user interaction, and high impact on confidentiality, integrity, and availability.

Potential Impact

Successful exploitation of this vulnerability could result in complete compromise of the affected PLC's confidentiality, integrity, and availability. This could disrupt industrial control processes relying on the Modicon M580, potentially causing operational failures or unauthorized control.

Mitigation Recommendations

No patch or official fix information is currently available for this vulnerability. Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until a fix is released, organizations should review application projects running on affected PLCs, especially those with lower application levels, and apply any recommended vendor mitigations once available.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
schneider
Date Reserved
2026-03-10T08:36:56.944Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 6aa41f3091cc7f384856d455

Added to database: 09/11/2026, 15:33:04 UTC

Last enriched: 09/11/2026, 15:46:51 UTC

Last updated: 09/11/2026, 16:48:03 UTC

Views: 5

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses