CVE-2026-39929: Out-of-bounds Read in Lakeside Software, LLC. SysTrack Agent

0
High
VulnerabilityCVE-2026-39929cvecve-2026-39929
Published: Thu May 28 2026 (05/28/2026, 21:14:12 UTC)
Source: CVE Database V5
Vendor/Project: Lakeside Software, LLC.
Product: SysTrack Agent

Description

An out-of-bounds read vulnerability exists in Lakeside Software's SysTrack Agent versions prior to 11. 2. 1. 28, 11. 3. 0. 38, 11. 4. 0. 24, and 11.

CVSS v4.0

Score 8.7high

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vuln. Confidentiality
None
Vuln. Integrity
None
Vuln. Availability
High
Subsq. Confidentiality
None
Subsq. Integrity
None
Subsq. Availability
None
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 05/28/2026, 21:48:47 UTC

Technical Analysis

CVE-2026-39929 is an out-of-bounds read vulnerability affecting the SysTrack Agent by Lakeside Software, LLC. The issue is triggered by sending a malformed UDP packet with an invalid memory address at a specific offset in the payload to the Command ID 30 handler. This causes an access violation leading to a denial of service by crashing the application. The vulnerability affects multiple versions prior to 11.2.1.28, 11.3.0.38, 11.4.0.24, and 11.5.0.15. The CVSS 4.0 base score is 8.7, indicating high severity, with attack vector network, no required privileges, and no user interaction needed. No known exploits are reported in the wild, and no official patch or remediation level has been disclosed.

Potential Impact

Successful exploitation results in a denial of service condition by crashing the SysTrack Agent application remotely without requiring authentication or user interaction. This could disrupt monitoring or management functions provided by the SysTrack Agent on affected systems. There is no indication of code execution or data disclosure from the available information.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is released, organizations should consider restricting or monitoring UDP traffic to the SysTrack Agent, especially packets targeting Command ID 30 handlers, to reduce exposure. No official remediation or temporary fix has been documented.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
VulnCheck
Date Reserved
2026-04-07T20:57:06.210Z
Cvss Version
4.0
State
PUBLISHED
Remediation Level
null

Threat ID: 6a18b4aee29bf47b5032f456

Added to database: 5/28/2026, 9:33:34 PM

Last enriched: 5/28/2026, 9:48:47 PM

Last updated: 5/28/2026, 10:39:41 PM

Views: 4

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses