CVE-2026-42806: Bosch Sensortec BME690 SensorAPI (C) · Out-of-bounds Read
Affects Bosch Sensortec BME690 SensorAPI (C)Source CVE Database V5
Not known to be exploited · CVSS 4.3 Medium.
Data as of 26 Oct 2026, 10:12 UTC
- EPSS
- 0.2% chance of exploitation in 30 days – higher than 10% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- CISA SSVC
- Exploitation
- No evidence of active exploitation and no public proof of concept
- Automatable
- Attackers cannot reliably automate steps 1–4 of the kill chain
- Technical impact
- Limited control over the software or limited information exposure
CISA SSVC assessment, 2026-09-10.
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:LExploitation evidence
Disclosed: evidence found.
CVE published 10 Sep 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| Bosch SensortecBME690 SensorAPI (C) | Affected
| Fixed in– |
Description
An out-of-bounds read vulnerability was discovered in the Bosch BME690 SensorAPI (C-driver) in version v1.0.3 and prior, specifically within the field data parsing logic in read_all_field_data (bme69x.c). The driver prefetches heater configuration registers into a contiguous 30-byte stack buffer (set_val) mapping IDAC, RES_HEAT, and GAS_WAIT tables. When parsing sensor field data, the gas_index is extracted using a 4-bit mask (0..15) but lacks boundary verification against the valid range (0..9). An attacker or a compromised peripheral mimicking a sensor on the I2C/SPI bus could return a payload with a gas index value of 10 or higher. This causes the driver to perform an out-of-bounds array access (set_val[20 + gas_index]), reading up to 6 bytes past the stack buffer. The leaked out-of-bounds byte is then written into the public gas_wait field, which may lead to measurement corruption or leak adjacent stack memory when telemetered or logged.