Skip to main content
VulnerabilityPublished Updated

CVE-2026-43203: Linux kernel · atm: fore200e: fix use-after-free in tasklets during device removal

Affects Linux kernelSource GCVE Database

0
Compare

Not known to be exploited · CVSS 7.5 High.

Data as of 11 Nov 2026, 23:24 UTC

CVSS 3.1 base score
7.5High
How severe the flaw is on the 0–10 CVSS scale.

Thin evidence

One scorer or none
CVSS scores by source
CNA (Linux)CVSS 3.17.5
EPSS
0.4% chance of exploitation in 30 days – higher than 34% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 6 May 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 11 Nov 2026.

Description

In the Linux kernel, the following vulnerability has been resolved: atm: fore200e: fix use-after-free in tasklets during device removal When the PCA-200E or SBA-200E adapter is being detached, the fore200e is deallocated. However, the tx_tasklet or rx_tasklet may still be running or pending, leading to use-after-free bug when the already freed fore200e is accessed again in fore200e_tx_tasklet() or fore200e_rx_tasklet(). One of the race conditions can occur as follows: CPU 0 (cleanup) | CPU 1 (tasklet) fore200e_pca_remove_one() | fore200e_interrupt() fore200e_shutdown() | tasklet_schedule() kfree(fore200e) | fore200e_tx_tasklet() | fore200e-> // UAF Fix this by ensuring tx_tasklet or rx_tasklet is properly canceled before the fore200e is released. Add tasklet_kill() in fore200e_shutdown() to synchronize with any pending or running tasklets. Moreover, since fore200e_reset() could prevent further interrupts or data transfers, the tasklet_kill() should be placed after fore200e_reset() to prevent the tasklet from being rescheduled in fore200e_interrupt(). Finally, it only needs to do tasklet_kill() when the fore200e state is greater than or equal to FORE200E_STATE_IRQ, since tasklets are uninitialized in earlier states. In a word, the tasklet_kill() should be placed in the FORE200E_STATE_IRQ branch within the switch...case structure. This bug was identified through static analysis.

References

Community reviews