CVE-2026-45723: siderolabs omni · Improper Input Validation
Affects siderolabs omniSource CVE Database V5
Not known to be exploited · CVSS 2.7 Low : upgrade to 1.7.3 or 1.6.6 when convenient.
Data as of 1 Nov 2026, 11:02 UTC
- EPSS
- 0.4% chance of exploitation in 30 days – higher than 42% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- Patch
- Available – fixed in 1.7.3, 1.6.6
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:NExploitation evidence
Disclosed: evidence found.
CVE published 17 Sep 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 1 Nov 2026.
What to do
Upgrade omni and siderolabs/omni to 1.7.3 or 1.6.6.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| siderolabsomni | Affected
| Fixed in
|
| siderolabsomni | Affected
| Fixed in
|
GitHubsiderolabs/omnipkg:github/siderolabs/omniOther threats | Affected
| Fixed in
|
Check your own hosts for these packages with threat-finder (opens in a new tab), our free open-source scanner.
AI-suggested
Upgrade to siderolabs omni version 1.6.6 or later, or 1.7.3 or later, where this vulnerability is fixed. No other mitigation is required as the issue is resolved in these versions.
Description
CVE-2026-45723 is an improper input validation vulnerability in siderolabs omni prior to versions 1.6.6 and 1.7.3. An authenticated Operator can manipulate the TalosVersion field to cause the application to issue HTTP GET requests to unintended paths on the configured image-factory host. This can lead to same-host endpoint probing and possible disclosure of internal diagnostic information. The vulnerability does not allow redirection to other hosts or write operations. The issue is fixed in versions 1.6.6 and 1.7.3.
References
- github.com/siderolabs/omni/security/advisories/GHSA-c66c-vq6w-fvh5 (opens in a new tab)
- github.com/siderolabs/omni/pull/2817 (opens in a new tab)
- github.com/siderolabs/omni/commit/13c3f289789842e1fd954d98babb34b94eea1192 (opens in a new tab)
- github.com/siderolabs/omni/commit/3e69e80802624bf322f16aa499d5eafca16d0025 (opens in a new tab)
- github.com/siderolabs/omni/commit/9426c2cabccaa1d442bc8ebf28c16cae2d7c6ff7 (opens in a new tab)
- github.com/siderolabs/omni/releases/tag/v1.6.6 (opens in a new tab)
- github.com/siderolabs/omni/releases/tag/v1.7.3 (opens in a new tab)