CVE-2026-45832: CWE-639 Authorization bypass through User-Controlled key in Chroma ChromaDB
All V1 collection-level endpoints in ChromaDB's Python project pass None for the tenant and database to the authorization layer, allowing attackers to bypass authorization controls by using the V1 endpoints.
AI Analysis
Technical Summary
In ChromaDB Python project version 0.5.0, all V1 collection-level endpoints fail to properly enforce authorization because they pass None values for tenant and database to the authorization layer. This allows attackers with limited privileges to bypass authorization checks by exploiting these V1 endpoints, effectively gaining unauthorized access to resources. The vulnerability is classified as CWE-639 (Authorization Bypass Through User-Controlled Key). The CVSS 4.0 base score is 8.8, indicating a high severity with network attack vector, low attack complexity, and no user interaction required. No official patch or remediation guidance has been published yet, and no known exploits are reported in the wild.
Potential Impact
Attackers can bypass authorization controls on V1 collection-level endpoints in ChromaDB Python project version 0.5.0, potentially gaining unauthorized access to data or functionality that should be restricted. This compromises the confidentiality and integrity of the affected system. The vulnerability requires low privileges to exploit and can be triggered remotely without user interaction.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, avoid using the V1 collection-level endpoints or implement additional access controls outside the affected authorization layer to mitigate unauthorized access risks.
CVE-2026-45832: CWE-639 Authorization bypass through User-Controlled key in Chroma ChromaDB
Description
All V1 collection-level endpoints in ChromaDB's Python project pass None for the tenant and database to the authorization layer, allowing attackers to bypass authorization controls by using the V1 endpoints.
CVSS v4.0
Score 8.8high
Affected software
Run on your own infrastructure? Check whether these packages are installed with threat-finder — our free open-source scanner.
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
In ChromaDB Python project version 0.5.0, all V1 collection-level endpoints fail to properly enforce authorization because they pass None values for tenant and database to the authorization layer. This allows attackers with limited privileges to bypass authorization checks by exploiting these V1 endpoints, effectively gaining unauthorized access to resources. The vulnerability is classified as CWE-639 (Authorization Bypass Through User-Controlled Key). The CVSS 4.0 base score is 8.8, indicating a high severity with network attack vector, low attack complexity, and no user interaction required. No official patch or remediation guidance has been published yet, and no known exploits are reported in the wild.
Potential Impact
Attackers can bypass authorization controls on V1 collection-level endpoints in ChromaDB Python project version 0.5.0, potentially gaining unauthorized access to data or functionality that should be restricted. This compromises the confidentiality and integrity of the affected system. The vulnerability requires low privileges to exploit and can be triggered remotely without user interaction.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, avoid using the V1 collection-level endpoints or implement additional access controls outside the affected authorization layer to mitigate unauthorized access risks.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- HiddenLayer
- Date Reserved
- 2026-05-13T14:01:39.604Z
- Cvss Version
- 4.0
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a2c2836e617e2d83487d714
Added to database: 6/12/2026, 3:39:34 PM
Last enriched: 6/12/2026, 3:56:45 PM
Last updated: 6/12/2026, 7:29:35 PM
Views: 7
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.