Skip to main content
VulnerabilityPublished

CVE-2026-4638: Paessler PRTG Network Monitor · Generation of error message containing sensitive information

Affects Paessler PRTG Network MonitorSource CVE Database V5

0
Compare

Not known to be exploited · CVSS 7.1 High : upgrade to 26.2.120.1449 soon.

Data as of 6 Nov 2026, 23:24 UTC

CVSS 4.0 base score
7.1High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.3% chance of exploitation in 30 days – higher than 23% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
Patch
Available – fixed in 26.2.120.1449
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 24 Sep 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 7 Nov 2026.

What to do

Upgrade Paessler PRTG Network Monitor to 26.2.120.1449.

Affected software

ProductAffectedFixed in
Paessler GmbHPRTG Network MonitorAffected
  • <26.2.120.1449
Fixed in
  • 26.2.120.1449

AI-suggested

A fixed version 26.2.120.1449 or later addresses this issue. Users should upgrade PRTG Network Monitor to version 26.2.120.1449 or newer to remediate the vulnerability. No other mitigation or workaround is documented. Since this is not a cloud service, remediation depends on user upgrade.

Description

PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter. Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.

References

Community reviews

Loading reviews…