CVE-2026-54800: CWE-1188: Initialization of a Resource with an Insecure Default in Siemens CPCI85 Central Processing/Communication
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0). The affected application ships with a default configuration that disables all OPC UA security mechanisms. This could allow an attacker to gain unauthorized access and control over critical system functions.
AI Analysis
Technical Summary
This vulnerability (CVE-2026-54800) involves an insecure default configuration in Siemens CPCI85 Central Processing/Communication and SICORE Base system software versions before V26.20. The default settings disable OPC UA security mechanisms, which are designed to protect communication and control functions. As a result, an attacker could gain unauthorized access and manipulate critical system functions. The CVSS 3.1 base score is 4.8 (medium), reflecting network attack vector, high attack complexity, no privileges required, no user interaction, and low impact on confidentiality and integrity, with no impact on availability. No official patch or remediation level has been published yet, and no known exploits are reported in the wild.
Potential Impact
The vulnerability could allow an attacker to bypass security controls by exploiting the insecure default configuration that disables OPC UA security mechanisms. This may lead to unauthorized access and control over critical system functions, potentially compromising system integrity and confidentiality. However, the impact is rated as low for confidentiality and integrity, with no availability impact, and exploitation complexity is high.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix or guidance is provided by Siemens, users should review and manually enable OPC UA security mechanisms in their configurations to mitigate the risk of unauthorized access. Monitor Siemens advisories for updates on patches or official mitigations.
CVE-2026-54800: CWE-1188: Initialization of a Resource with an Insecure Default in Siemens CPCI85 Central Processing/Communication
Description
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0). The affected application ships with a default configuration that disables all OPC UA security mechanisms. This could allow an attacker to gain unauthorized access and control over critical system functions.
CVSS v3.1
Score 4.8medium
Affected software
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
This vulnerability (CVE-2026-54800) involves an insecure default configuration in Siemens CPCI85 Central Processing/Communication and SICORE Base system software versions before V26.20. The default settings disable OPC UA security mechanisms, which are designed to protect communication and control functions. As a result, an attacker could gain unauthorized access and manipulate critical system functions. The CVSS 3.1 base score is 4.8 (medium), reflecting network attack vector, high attack complexity, no privileges required, no user interaction, and low impact on confidentiality and integrity, with no impact on availability. No official patch or remediation level has been published yet, and no known exploits are reported in the wild.
Potential Impact
The vulnerability could allow an attacker to bypass security controls by exploiting the insecure default configuration that disables OPC UA security mechanisms. This may lead to unauthorized access and control over critical system functions, potentially compromising system integrity and confidentiality. However, the impact is rated as low for confidentiality and integrity, with no availability impact, and exploitation complexity is high.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix or guidance is provided by Siemens, users should review and manually enable OPC UA security mechanisms in their configurations to mitigate the risk of unauthorized access. Monitor Siemens advisories for updates on patches or official mitigations.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- siemens
- Date Reserved
- 2026-06-16T07:47:12.274Z
- Cvss Version
- 3.1
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a4fb12f68715ace43893255
Added to database: 07/09/2026, 14:33:19 UTC
Last enriched: 07/09/2026, 14:47:54 UTC
Last updated: 07/09/2026, 15:33:27 UTC
Views: 5
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.