Skip to main content
VulnerabilityPublished Updated

CVE-2026-58115: Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) · Missing Authentication for Critical Functionality

Affects Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)Source CVE Database V5

0
Compare

Not known to be exploited · CVSS 10.0 Critical : upgrade to 4.3.4-1 as a priority.

Data as of 10 Nov 2026, 23:24 UTC

CVSS 3.1 base score
10.0Critical
How severe the flaw is on the 0–10 CVSS scale.

Thin evidence

One scorer or none
CVSS scores by source
CNA (siemens)CVSS 3.110.0
CNA (siemens)CVSS 4.010.0
EPSS
0.8% chance of exploitation in 30 days – higher than 59% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
Patch
Available – fixed in 4.3.4-1
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 11 Aug 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: evidence found.

    Public exploit code: GitHub proofs of concept

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), GitHub proofs of concept, the Metasploit, Exploit-DB and nuclei-templates index as of 10 Nov 2026.

What to do

Upgrade SIMATIC IoT2050 to 4.3.4-1.

Affected software

ProductAffectedFixed in
SiemensSIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)Affected
  • <4.3.4-1
Fixed in
  • 4.3.4-1
SiemensSIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)Affected
  • All versions
Fixed in–
SiemensSIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2)Affected
  • <4.3.4-1
Fixed in
  • 4.3.4-1
SiemensSIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2)Affected
  • All versions
Fixed in–
SiemensSIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2)Affected
  • <4.3.4-1
Fixed in
  • 4.3.4-1
SiemensSIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2)Affected
  • All versions
Fixed in–

AI-suggested

If you cannot patch yet, restrict network access to the Node-RED HTTP interface to trusted networks only and monitor for unauthorized access attempts. Do not expose the interface to untrusted networks.

Description

A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions running Example Image versions with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.

Reports on CVE-2026-58115

References

Community reviews