Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2026-59693: CWE-754: Improper Check for Unusual or Exceptional Conditions in Siemens Desigo DXR2

0
Medium
VulnerabilityCVE-2026-59693cvecve-2026-59693cwe-754
Published: 08/11/2026 (08/11/2026, 12:20:26 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: Desigo DXR2

Description

A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.233.16-7862), Desigo PXC3 (All versions < V01.21.233.16-7862), Desigo PXC4 (All versions < V02.21.194.36-2715), Desigo PXC5.E003 (All versions < V02.21.194.36-2715), Desigo PXC5.E24 (All versions < V02.21.194.36-2715), Desigo PXC7 (All versions < V02.21.194.36-2715). The affected devices are vulnerable to a denial-of-service (DoS) vulnerability. An attacker can exploit this issue by sending a malformed BACnet packet, causing the device to stop responding to BACnet queries. Recovery requires a device reset or reboot to restore normal functionality.

CVSS v3.1

Score 4.3medium

Attack Vector
Adjacent Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
Low
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

Affected software

Affected versions
<V01.21.233.16-7862<V02.21.194.36-2715

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 08/11/2026, 13:01:41 UTC

Technical Analysis

CVE-2026-59693 is a denial-of-service vulnerability in Siemens Desigo DXR2 and several Desigo PXC devices caused by improper checking for unusual or exceptional conditions (CWE-754). An attacker can send a malformed BACnet packet to cause the affected device to become unresponsive to BACnet queries. Recovery from this state requires a device reset or reboot. The affected versions are all versions prior to V01.21.233.16-7862 for Desigo DXR2 and Desigo PXC3, and prior to V02.21.194.36-2715 for Desigo PXC4, PXC5.E003, PXC5.E24, and PXC7. No official patch or remediation level has been published yet.

Potential Impact

Exploitation results in a denial-of-service condition where the affected Siemens devices stop responding to BACnet queries, disrupting normal device communication and operation. There is no impact on confidentiality or integrity, only availability is affected.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until a fix is available, affected devices may require manual reset or reboot after exploitation to restore functionality.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
siemens
Date Reserved
2026-07-06T13:50:39.917Z
Cvss Version
3.1
State
PUBLISHED
Remediation Level
null

Threat ID: 6a7b18a1bf8831d539b860fb

Added to database: 08/11/2026, 12:42:09 UTC

Last enriched: 08/11/2026, 13:01:41 UTC

Last updated: 08/12/2026, 02:40:59 UTC

Views: 7

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses