Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2026-59700: CWE-125: Out-of-bounds Read in Siemens Simcenter Femap

0
High
VulnerabilityCVE-2026-59700cvecve-2026-59700cwe-125
Published: 08/11/2026 (08/11/2026, 12:20:27 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: Simcenter Femap

Description

An out-of-bounds read vulnerability exists in Siemens Simcenter Femap versions prior to V2606.0001. The flaw occurs when parsing specially crafted BMP files and may allow an attacker to execute code within the context of the current process. The vulnerability has a high severity rating with a CVSS score of 7.8. No official patch or remediation guidance has been provided yet by the vendor. There are no known exploits in the wild at this time.

CVSS v3.1

Score 7.8high

Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Affected software

Affected versions
<2606.0001

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 08/11/2026, 13:01:57 UTC

Technical Analysis

CVE-2026-59700 is an out-of-bounds read vulnerability (CWE-125) in Siemens Simcenter Femap affecting all versions before V2606.0001. The vulnerability occurs during the parsing of specially crafted BMP files, potentially enabling code execution in the context of the current process. The CVSS 3.1 base score is 7.8, indicating high severity with local attack vector, low attack complexity, no privileges required, user interaction required, and impacts to confidentiality, integrity, and availability. No vendor advisory or patch information is currently available, and no known exploits have been reported.

Potential Impact

Successful exploitation could allow an attacker to execute arbitrary code with the privileges of the user running Simcenter Femap, potentially leading to full compromise of the affected system's confidentiality, integrity, and availability.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until a patch is available, avoid opening untrusted BMP files with Simcenter Femap and apply standard security best practices to limit exposure.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
siemens
Date Reserved
2026-07-06T15:11:37.370Z
Cvss Version
3.1
State
PUBLISHED
Remediation Level
null

Threat ID: 6a7b18a1bf8831d539b860fe

Added to database: 08/11/2026, 12:42:09 UTC

Last enriched: 08/11/2026, 13:01:57 UTC

Last updated: 08/12/2026, 03:40:59 UTC

Views: 6

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses