Skip to main content
EPSS 0.3%top 81%

CVE-2026-62653: CWE-787: Out-of-bounds Write in Siemens Reyrolle 7SR5

0
Medium
VulnerabilityCVE-2026-62653cvecve-2026-62653cwe-787
Published: 09/08/2026 (09/08/2026, 08:11:34 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: Reyrolle 7SR5

Description

A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The input received over a proprietary communication protocol that is exposed when the device is placed into a special firmware-update mode is not properly validated, resulting in a memory corruption condition. This could allow an unauthenticated attacker with physical access to the device to cause a crash and potentially execute arbitrary code on the device.

CVSS v3.1

Score 6.8medium

Attack Vector
Physical
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected software

Siemens

Reyrolle 7SR5

Affected versions
>=0 <2.70

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 09/16/2026, 01:09:00 UTC

Technical Analysis

This vulnerability (CWE-787) exists in Siemens Reyrolle 7SR5 versions before 2.70. It arises from insufficient input validation over a proprietary communication protocol exposed only in firmware-update mode, leading to memory corruption. Exploitation requires physical access and no authentication, allowing an attacker to cause denial of service or potentially arbitrary code execution.

Potential Impact

Successful exploitation can lead to a complete compromise of the affected device, including denial of service (crash) and arbitrary code execution with high confidentiality, integrity, and availability impact. The attack requires physical access and no privileges or user interaction, limiting remote exploitation possibilities.

Mitigation Recommendations

A fixed version 2.70 or later should be applied once available. Since no patch links or vendor advisory are provided, patch status is not yet confirmed — check Siemens' official advisory for current remediation guidance. Until patched, restrict physical access to the device and avoid placing it in firmware-update mode unless necessary.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
siemens
Date Reserved
2026-07-14T16:24:23.430Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6a9fc956acd9273b49571db0

Added to database: 09/08/2026, 08:37:42 UTC

Last enriched: 09/16/2026, 01:09:00 UTC

Last updated: 10/23/2026, 15:12:05 UTC

Views: 78

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses