Skip to main content
EPSS 0.2%top 92%

CVE-2026-64203: CWE-125 Out-of-bounds read in NI LabVIEW

0
High
VulnerabilityCVE-2026-64203cvecve-2026-64203cwe-125
Published: 08/25/2026 (08/25/2026, 16:48:40 UTC)
Source: CVE Database V5
Vendor/Project: NI
Product: LabVIEW

Description

CVE-2026-64203 is a high-severity memory corruption vulnerability in NI LabVIEW that can lead to information disclosure or arbitrary code execution. Exploitation requires a user to open a specially crafted VI file. This affects NI LabVIEW 2026 Q3 (26.3.0) and prior versions, including specific versions 23.1.0, 24.1.0, 25.1.0, and 26.1.0. There is no confirmed patch or official remediation available yet. The vulnerability involves an out-of-bounds read (CWE-125).

CVSS v3.1

Score 7.8high

Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Affected software

NI

LabVIEW

Affected versions
>=0 <23.0.0>=23.1.0 <23.3.10>=24.1.0 <24.3.7>=25.1.0 <25.3.5>=26.1.0 <26.3.1

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 09/10/2026, 03:22:19 UTC

Technical Analysis

This vulnerability in NI LabVIEW is caused by an out-of-bounds read (CWE-125) that may result in memory corruption. Successful exploitation requires user interaction by opening a malicious VI file, potentially leading to information disclosure or arbitrary code execution. The CVSS v3.1 base score is 7.8, indicating high severity, with attack vector local, low attack complexity, no privileges required, user interaction required, and impacts to confidentiality, integrity, and availability. Affected versions explicitly include 23.1.0, 24.1.0, 25.1.0, and 26.1.0. No vendor advisory or patch information is currently available to confirm remediation status.

Potential Impact

The vulnerability allows an attacker to cause memory corruption that can lead to information disclosure or arbitrary code execution on affected systems. Exploitation requires local access and user interaction, specifically opening a crafted VI file. The impact affects confidentiality, integrity, and availability of the system running NI LabVIEW.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until a fix is available, users should avoid opening VI files from untrusted sources to mitigate risk.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
NI
Date Reserved
2026-07-19T15:12:06.826Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6a8dcc10acd9273b4979f620

Added to database: 08/25/2026, 17:08:32 UTC

Last enriched: 09/10/2026, 03:22:19 UTC

Last updated: 10/09/2026, 18:48:21 UTC

Views: 64

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses