CVE-2026-69187: LabRedesCefetRJ WeGIA · Incorrect Privilege Assignment
Affects LabRedesCefetRJ WeGIASource CVE Database V5
Not known to be exploited · CVSS 8.8 High : upgrade to 3.9.1 soon.
Data as of 17 Nov 2026, 22:49 UTC
Thin evidence
One scorer or none| CNA (GitHub_M) | CVSS 3.1 | 8.8 |
|---|
- Patch
- Available – fixed in 3.9.1
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HExploitation evidence
Disclosed: evidence found.
CVE published 17 Nov 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 17 Nov 2026.
What to do
Upgrade LabRedesCefetRJ WeGIA to 3.9.1.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| LabRedesCefetRJWeGIA | Affected
| Fixed in
|
AI-suggested
This vulnerability is fixed in WeGIA version 3.9.1. Users should upgrade to version 3.9.1 or later to remediate this issue. No additional mitigation actions are indicated by the vendor advisory.
Description
WeGIA is a web manager for charitable institutions. Prior to 3.9.1, web/controle/control.php authorizes FuncionarioControle requests only by checking whether an authenticated employee has a permission row for resource 11 or 91, while MiddlewareDAO::verificarPermissao() does not compare the stored id_acao value or authorize the requested method. An employee with any such permission and a valid CSRF token from the employee's own session can invoke FuncionarioControle::adicionarPermissao, FuncionarioControle::alterarPermissao, or FuncionarioControle::excluirPermissao to add, change, or remove permissions for arbitrary roles. This can grant higher action levels over sensitive resources, expose or modify protected employee, patient, configuration, and administrative data, or disrupt legitimate access by changing other roles. This issue is fixed in version 3.9.1.
References
- github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-27h8-4v64-8v85 (opens in a new tab)
- github.com/LabRedesCefetRJ/WeGIA/pull/1892 (opens in a new tab)
- github.com/LabRedesCefetRJ/WeGIA/commit/9fb18f330ea31b240713812010690418cb3d0eed (opens in a new tab)
- github.com/LabRedesCefetRJ/WeGIA/releases/tag/3.9.0 (opens in a new tab)