Skip to main content
VulnerabilityPublished Updated

CVE-2026-72895: Siemens SIMATIC IPC BX-21A · Use of Default Cryptographic Key

Affects Siemens SIMATIC IPC BX-21ASource CVE Database V5

0
Compare

Not known to be exploited · CVSS 7.7 High : upgrade to 31.01.13 soon.

Data as of 27 Nov 2026, 22:52 UTC

CVSS 3.1 base score
7.7High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.1% chance of exploitation in 30 days – higher than 1% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
Patch
Available – fixed in 31.01.13, 1.1.4, 28.01.15
CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 13 Oct 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 28 Nov 2026.

What to do

Upgrade SIMATIC to 31.01.13 (IPC BX-21A) or 1.1.4 (IPC RW-543A) or 28.01.15 (IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G).

Affected software

ProductAffectedFixed in
SiemensSIMATIC IPC BX-21AAffected
  • <31.01.13
Fixed in
  • 31.01.13
SiemensSIMATIC IPC RW-543AAffected
  • <1.1.4
Fixed in
  • 1.1.4
SiemensSIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377GAffected
  • <28.01.15
Fixed in
  • 28.01.15

AI-suggested

If you cannot patch yet, restrict physical and administrative access to affected devices to mitigate exploitation risk.

Description

A vulnerability in Siemens SIMATIC IPC BX-21A and related models allows bypassing UEFI Secure Boot protections due to the presence of a BIOS vendor test key in the UEFI Secure Boot key database. This affects all versions prior to V31.01.13 for IPC BX-21A, prior to V1.1.4 for IPC RW-543A, and prior to V28.01.15 for IPC227G, IPC277G, IPC277G PRO, IPC327G, and IPC377G. An attacker with local physical or administrative access could exploit this to boot unauthorized operating systems or UEFI applications, potentially compromising device confidentiality, integrity, and availability.