CVE-2026-73618: Improper Neutralization of Special Elements in Data Query Logic in budibase server
Budibase Server before 3.40.0 contains a NoSQL injection vulnerability in the MongoDB query execution endpoint where user-supplied parameters are interpolated into JSON query templates without proper sanitization of JSON metacharacters. Attackers with query write permission can inject JSON structural characters to alter MongoDB queries, bypassing filters to read, modify, or delete arbitrary documents.
AI Analysis
Technical Summary
CVE-2026-73618 is a NoSQL injection vulnerability affecting Budibase Server prior to version 3.40.0. The flaw arises from improper neutralization of special elements in data query logic, specifically in the MongoDB query execution endpoint. User input is directly interpolated into JSON query templates without adequate sanitization of JSON metacharacters, allowing attackers with query write permissions to inject JSON structural characters. This injection can alter the intended MongoDB queries, enabling unauthorized access to read, modify, or delete arbitrary documents within the database.
Potential Impact
Exploitation of this vulnerability allows an attacker with query write permissions to bypass query filters and manipulate MongoDB queries. This can lead to unauthorized disclosure, modification, or deletion of data stored in the Budibase Server database. The CVSS 4.0 score of 8.7 reflects a high severity due to network attack vector, low attack complexity, no user interaction, and high impact on confidentiality and integrity.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict query write permissions to trusted users only and monitor for suspicious query activity. Avoid exposing the MongoDB query execution endpoint to untrusted networks or users.
CVE-2026-73618: Improper Neutralization of Special Elements in Data Query Logic in budibase server
Description
Budibase Server before 3.40.0 contains a NoSQL injection vulnerability in the MongoDB query execution endpoint where user-supplied parameters are interpolated into JSON query templates without proper sanitization of JSON metacharacters. Attackers with query write permission can inject JSON structural characters to alter MongoDB queries, bypassing filters to read, modify, or delete arbitrary documents.
CVSS v4.0
Score 8.7high
Affected software
Run on your own infrastructure? Check whether these packages are installed with threat-finder — our free open-source scanner.
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2026-73618 is a NoSQL injection vulnerability affecting Budibase Server prior to version 3.40.0. The flaw arises from improper neutralization of special elements in data query logic, specifically in the MongoDB query execution endpoint. User input is directly interpolated into JSON query templates without adequate sanitization of JSON metacharacters, allowing attackers with query write permissions to inject JSON structural characters. This injection can alter the intended MongoDB queries, enabling unauthorized access to read, modify, or delete arbitrary documents within the database.
Potential Impact
Exploitation of this vulnerability allows an attacker with query write permissions to bypass query filters and manipulate MongoDB queries. This can lead to unauthorized disclosure, modification, or deletion of data stored in the Budibase Server database. The CVSS 4.0 score of 8.7 reflects a high severity due to network attack vector, low attack complexity, no user interaction, and high impact on confidentiality and integrity.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict query write permissions to trusted users only and monitor for suspicious query activity. Avoid exposing the MongoDB query execution endpoint to untrusted networks or users.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- VulnCheck
- Date Reserved
- 2026-08-13T11:16:27.835Z
- Cvss Version
- 4.0
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a7dbdfbbf8831d5393225e7
Added to database: 08/13/2026, 12:52:11 UTC
Last enriched: 08/13/2026, 12:56:07 UTC
Last updated: 08/13/2026, 13:26:45 UTC
Views: 3
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.