CVE-2026-85104: CWE-924 Improper enforcement of message integrity during transmission in a communication channel in Sooma Sooma tDCS Home Therapy
In Sooma 2GEN brain stimulator, an attacker within Bluetooth range can make unauthenticated changes to brain stimulation parameters.
AI Analysis
Technical Summary
The vulnerability identified as CVE-2026-85104 affects the Sooma 2GEN brain stimulator, part of the Sooma tDCS Home Therapy product line. It is classified under CWE-924, indicating improper enforcement of message integrity during transmission in a communication channel. Specifically, an attacker within Bluetooth range can alter brain stimulation parameters without authentication due to insufficient integrity checks in the Bluetooth communication channel.
Potential Impact
An attacker within Bluetooth range can make unauthorized changes to brain stimulation parameters on the affected device. This could lead to unintended or harmful stimulation settings being applied to the user. The CVSS 4.0 base score is 5.3 (medium), reflecting the local attack vector with low complexity and no required privileges or user interaction, but with limited impact on confidentiality and integrity and low impact on availability.
Mitigation Recommendations
No patch or official fix information is provided in the available data. Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until a fix is available, users should limit Bluetooth exposure and ensure the device is used in secure environments to reduce the risk of unauthorized access.
CVE-2026-85104: CWE-924 Improper enforcement of message integrity during transmission in a communication channel in Sooma Sooma tDCS Home Therapy
Description
In Sooma 2GEN brain stimulator, an attacker within Bluetooth range can make unauthenticated changes to brain stimulation parameters.
CVSS v4.0
Score 5.3medium
Affected software
Sooma
Sooma tDCS Home Therapy
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
The vulnerability identified as CVE-2026-85104 affects the Sooma 2GEN brain stimulator, part of the Sooma tDCS Home Therapy product line. It is classified under CWE-924, indicating improper enforcement of message integrity during transmission in a communication channel. Specifically, an attacker within Bluetooth range can alter brain stimulation parameters without authentication due to insufficient integrity checks in the Bluetooth communication channel.
Potential Impact
An attacker within Bluetooth range can make unauthorized changes to brain stimulation parameters on the affected device. This could lead to unintended or harmful stimulation settings being applied to the user. The CVSS 4.0 base score is 5.3 (medium), reflecting the local attack vector with low complexity and no required privileges or user interaction, but with limited impact on confidentiality and integrity and low impact on availability.
Mitigation Recommendations
No patch or official fix information is provided in the available data. Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until a fix is available, users should limit Bluetooth exposure and ensure the device is used in secure environments to reduce the risk of unauthorized access.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- NCSC-FI
- Date Reserved
- 2026-09-03T06:44:36.452Z
- Cvss Version
- 4.0
- State
- PUBLISHED
Threat ID: 6aaa9de655bf5e2cf5afad91
Added to database: 09/16/2026, 13:47:18 UTC
Last enriched: 09/16/2026, 14:01:33 UTC
Last updated: 09/17/2026, 04:26:53 UTC
Views: 11
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.