Skip to main content

CVE-2026-89200: CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') in Siemens RUGGEDCOM CROSSBOW

0
Medium
VulnerabilityCVE-2026-89200cvecve-2026-89200cwe-89
Published: 10/13/2026 (10/13/2026, 09:19:04 UTC)
Source: CVE Database V5
Vendor/Project: Siemens
Product: RUGGEDCOM CROSSBOW

Description

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in the Name and Value fields for custom file labels. This could allow an authenticated attacker with administrative privileges to execute arbitrary SQL commands on the underlying database.

CVSS v3.1

Score 6.7medium

Attack Vector
Local
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Affected software

Siemens

RUGGEDCOM CROSSBOW

Affected versions
>=0 <6.0

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 10/13/2026, 10:03:58 UTC

Technical Analysis

This vulnerability in Siemens RUGGEDCOM CROSSBOW (all versions before 6.0) involves improper neutralization of special elements in SQL commands (CWE-89). Specifically, the Name and Value fields for custom file labels do not properly validate or sanitize input, allowing an authenticated administrator to perform arbitrary SQL injection attacks on the backend database. The CVSS 3.1 base score is 6.7, indicating a medium severity with high impact on confidentiality, integrity, and availability. The attack vector requires local access with high privileges and no user interaction.

Potential Impact

Successful exploitation allows an authenticated attacker with administrative privileges to execute arbitrary SQL commands on the device's database, potentially leading to full compromise of data confidentiality, integrity, and availability within the affected system.

Mitigation Recommendations

A fix is available in Siemens RUGGEDCOM CROSSBOW version 6.0 and later. Users should upgrade to version 6.0 or above to remediate this vulnerability. Since no patch links or vendor advisory details are provided, verify with Siemens official resources for the latest remediation guidance.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
siemens
Date Reserved
2026-09-11T07:45:20.919Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6acdfe9e2cdf04f6564c88a4

Added to database: 10/13/2026, 09:49:18 UTC

Last enriched: 10/13/2026, 10:03:58 UTC

Last updated: 10/13/2026, 18:57:34 UTC

Views: 15

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses