Skip to main content

CVE-2026-90605: Buffer Overflow in Totolink A3002MU

0
Critical
Published: 09/14/2026 (09/14/2026, 00:31:29 UTC)
Source: CVE Database V5
Vendor/Project: Totolink
Product: A3002MU

Description

A weakness has been identified in Totolink A3002MU Hh-B20211125.1046. This vulnerability affects the function formFilter of the file /boafrm/formFilter of the component boa. Executing a manipulation of the argument ip6addr can lead to buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.

CVSS v4.0

Score 9.4critical

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vuln. Confidentiality
High
Vuln. Integrity
High
Vuln. Availability
High
Subsq. Confidentiality
High
Subsq. Integrity
High
Subsq. Availability
High
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P

Affected software

Totolink

A3002MU

CPE configurations
cpe:2.3:a:totolink:a3002mu:*:*:*:*:*:*:*:*

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 09/14/2026, 00:01:28 UTC

Technical Analysis

This vulnerability affects the Totolink A3002MU router's formFilter function within the /boafrm/formFilter component. A remote attacker can manipulate the ip6addr argument to trigger a buffer overflow condition. The vulnerability has a high CVSS 4.0 score of 9.4, indicating critical severity with network attack vector, low attack complexity, no privileges required, and no user interaction. Public exploit code is available, but no vendor patch or remediation details are provided in the input data.

Potential Impact

Successful exploitation can lead to a buffer overflow, potentially allowing remote code execution or denial of service on the affected device. Given the critical CVSS score and public exploit availability, this poses a significant risk to affected Totolink A3002MU devices if unmitigated.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, consider limiting network exposure of the affected device and monitoring for exploit attempts. No vendor advisory or patch links are provided in the current data.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
VulDB
Date Reserved
2026-09-12T19:30:28.764Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 6aa735f755bf5e2cf5394dc9

Added to database: 09/13/2026, 23:47:03 UTC

Last enriched: 09/14/2026, 00:01:28 UTC

Last updated: 09/14/2026, 03:40:11 UTC

Views: 9

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses