CVE-2026-9292: CWE-79 Improper neutralization of input during web page generation ('cross-site scripting') in Rockwell Automation FactoryTalk® DataMosaix™ Private Cloud
A Stored Cross-Site Scripting security issue exists within FactoryTalk® DataMosaix™ Private Cloud. The vulnerability stems from improper neutralization of user-supplied input within the Workflows configuration. An authenticated attacker with high privileges can inject malicious scripts that are permanently stored on the server. This vulnerability can result in the execution of malicious JavaScript when other users access the affected page, potentially allowing for account takeover, credential theft, or redirection to a malicious website.
AI Analysis
Technical Summary
This vulnerability is a stored cross-site scripting (CWE-79) issue in FactoryTalk® DataMosaix™ Private Cloud caused by improper neutralization of user-supplied input within the Workflows configuration. An attacker with authenticated high privileges can inject malicious JavaScript code that is permanently stored on the server. When other users view the affected pages, the malicious scripts execute in their browsers, which may result in account compromise or credential theft. The CVSS 4.0 base score is 8.4, reflecting network attack vector, low attack complexity, no privileges required for attack initiation beyond high privileges for injection, and high impact on confidentiality and integrity. No known exploits in the wild or vendor patches have been reported as of the publication date.
Potential Impact
Successful exploitation allows an authenticated attacker with high privileges to inject persistent malicious scripts into the application. These scripts execute in the context of other users' browsers when they access the affected pages, potentially enabling account takeover, credential theft, or redirection to malicious websites. This compromises confidentiality and integrity of user sessions and data within the affected application.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict high-privilege user access to trusted personnel only and monitor for suspicious activity related to the Workflows configuration. Avoid exposing affected pages to untrusted users. Follow Rockwell Automation advisories for updates on patches or mitigations.
CVE-2026-9292: CWE-79 Improper neutralization of input during web page generation ('cross-site scripting') in Rockwell Automation FactoryTalk® DataMosaix™ Private Cloud
Description
A Stored Cross-Site Scripting security issue exists within FactoryTalk® DataMosaix™ Private Cloud. The vulnerability stems from improper neutralization of user-supplied input within the Workflows configuration. An authenticated attacker with high privileges can inject malicious scripts that are permanently stored on the server. This vulnerability can result in the execution of malicious JavaScript when other users access the affected page, potentially allowing for account takeover, credential theft, or redirection to a malicious website.
CVSS v4.0
Score 8.4high
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
This vulnerability is a stored cross-site scripting (CWE-79) issue in FactoryTalk® DataMosaix™ Private Cloud caused by improper neutralization of user-supplied input within the Workflows configuration. An attacker with authenticated high privileges can inject malicious JavaScript code that is permanently stored on the server. When other users view the affected pages, the malicious scripts execute in their browsers, which may result in account compromise or credential theft. The CVSS 4.0 base score is 8.4, reflecting network attack vector, low attack complexity, no privileges required for attack initiation beyond high privileges for injection, and high impact on confidentiality and integrity. No known exploits in the wild or vendor patches have been reported as of the publication date.
Potential Impact
Successful exploitation allows an authenticated attacker with high privileges to inject persistent malicious scripts into the application. These scripts execute in the context of other users' browsers when they access the affected pages, potentially enabling account takeover, credential theft, or redirection to malicious websites. This compromises confidentiality and integrity of user sessions and data within the affected application.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict high-privilege user access to trusted personnel only and monitor for suspicious activity related to the Workflows configuration. Avoid exposing affected pages to untrusted users. Follow Rockwell Automation advisories for updates on patches or mitigations.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- Rockwell
- Date Reserved
- 2026-05-22T17:18:30.808Z
- Cvss Version
- 4.0
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a565a3f68715ace43c7b7db
Added to database: 07/14/2026, 15:48:15 UTC
Last enriched: 07/14/2026, 16:03:41 UTC
Last updated: 07/14/2026, 16:31:25 UTC
Views: 5
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.