CVE-2026-93289: CWE-78 Improper neutralization of special elements used in an OS command ('OS command injection') in Eufy Omni C20

0
Critical
VulnerabilityCVE-2026-93289cvecve-2026-93289cwe-78
Published: 09/24/2026 (09/24/2026, 19:24:40 UTC)
Source: CVE Database V5
Vendor/Project: Eufy
Product: Omni C20

Description

The affected products are vulnerable to command injection attack that could allow an unauthenticated attacker to execute system commands during the pairing process.

CVSS v4.0

Score 9.0critical

Attack Vector
Adjacent Network
Attack Complexity
High
Attack Requirements
Present
Privileges Required
None
User Interaction
None
Vuln. Confidentiality
High
Vuln. Integrity
High
Vuln. Availability
High
Subsq. Confidentiality
High
Subsq. Integrity
High
Subsq. Availability
High
CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Affected software

Eufy

Omni C20

Affected versions
>=0 <1.6.4

Eufy

Omni X10 Pro

Affected versions
>=0 <1.6.4
GitHub Actionsmore threats →ai
eufy/omni-c20
pkg:github/eufy/omni-c20
Affected versions
>=0 <1.6.4

Run on your own infrastructure? Check whether these packages are installed with threat-finder — our free open-source scanner.

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 09/24/2026, 19:47:57 UTC

Technical Analysis

This vulnerability (CWE-78) in the Eufy Omni C20 involves improper neutralization of special elements used in OS commands, enabling an unauthenticated attacker to inject and execute arbitrary system commands during the pairing process. The affected versions are >=0 and <1.6.4. The CVSS 4.0 vector indicates the attack requires adjacent network access with high attack complexity and privileges not required, but user interaction is not needed. The vulnerability impacts confidentiality, integrity, availability, system control, and system integrity at a high level.

Potential Impact

Successful exploitation could allow an unauthenticated attacker to execute arbitrary system commands on the affected device during pairing, potentially leading to full system compromise. This can affect device confidentiality, integrity, and availability.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until a fix is available, restrict access to the device's pairing process and monitor for suspicious activity during pairing attempts.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
icscert
Date Reserved
2026-09-17T16:04:33.101Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 6ab57b0af7a7c54106c05cae

Added to database: 09/24/2026, 19:33:30 UTC

Last enriched: 09/24/2026, 19:47:57 UTC

Last updated: 09/25/2026, 02:02:26 UTC

Views: 7

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses