Skip to main content
CVE-2026-133665VulnerabilityPublished

flowintel contains an information disclosure vulnerability that allows authenticated non-administrative users to

Source GCVE Database

0
Compare
Authoritative record:CVE-2026-133665· High 7.1

Not known to be exploited · CVSS 7.1 High : upgrade to 4.1.0 soon.

Data as of 20 Nov 2026, 13:48 UTC

CVSS 4.0 base score
7.1High
How severe the flaw is on the 0–10 CVSS scale.

Thin evidence

One scorer or none
CVSS scores by source
CNA (CIRCL)CVSS 4.07.1
Patch
Available – fixed in 4.1.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 20 Nov 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 19 Nov 2026.

What to do

Upgrade flowintel to 4.1.0.

Affected software

ProductAffectedFixed in
flowintelflowintelAffected
  • <4.1.0
Fixed in
  • 4.1.0
GitHubflowintelpkg:github/flowintelOther threatsAffected
  • <4.1.0
Fixed in
  • 4.1.0

Check your own hosts for these packages with threat-finder (opens in a new tab), our free open-source scanner.

AI-suggested

Upgrade to flowintel version 4.1.0 or later, where this information disclosure vulnerability has been addressed. Until patched, restrict access to non-administrative accounts and monitor for suspicious activity related to notification services. Patch status is confirmed by the version boundary provided.

Description

flowintel versions prior to 4.1.0 have an information disclosure vulnerability that allows authenticated non-administrative users to access sensitive configuration data and logs intended only for administrators. Sensitive fields exposed include webhook URLs, signing secrets, IMAP credentials, and delivery logs. Although the UI hides these configurations from non-admin users, the data remains accessible via page source or API responses, including historical webhook URLs that may contain active bearer tokens. This could enable unauthorized access to notification services and potential lateral movement within the infrastructure.

References

Community reviews