In Postgres Enterprise Manager (PEM), any PEM user can run the pem.send_webhook() function, which runs with elevated
Source GCVE Database
Not known to be exploited · CVSS 2.3 Low : upgrade to 10.6.1 when convenient.
Data as of 20 Nov 2026, 16:07 UTC
Thin evidence
One scorer or none| CNA (EDB) | CVSS 4.0 | 2.3 |
|---|
- Patch
- Available – fixed in 10.6.1
CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:N/VI:N/VA:N/SC:N/SI:L/SA:NExploitation evidence
Disclosed: evidence found.
CVE published 20 Nov 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 19 Nov 2026.
What to do
Upgrade Postgres Enterprise Manager to 10.6.1.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| EnterpriseDBPostgres Enterprise Manager | Affected
| Fixed in
|
AI-suggested
Upgrade to Postgres Enterprise Manager version 10.6.1 or later, where direct invocation of the pem.send_webhook() function by PEM login roles is blocked. No additional action is required as the vendor has implemented an official fix that restricts access to this function and ensures webhook notifications are sent only through controlled internal mechanisms.
Description
In Postgres Enterprise Manager (PEM), any PEM user could previously invoke the pem.send_webhook() function, which operates with elevated privileges to queue payloads for configured webhooks. This allowed users to send forged notifications using stored authentication tokens or certificates of those webhooks. Starting from PEM version 10.6.1, direct calls to this function by PEM login roles are blocked, and webhook notifications are sent only through internal PEM mechanisms.