CVE-2026-59309: CWE-303 Incorrect implementation of authentication algorithm in VMware Cloud Foundation
VMware vCenter in Cloud Foundation contains a critical authentication bypass vulnerability in the VMware Directory Service. This flaw allows an attacker with network access to bypass authentication and gain unauthorized access to the system. The vulnerability affects multiple versions of Cloud Foundation, including 5.x, 9.0.x.x, and 9.1.x.x. The vulnerability has a CVSS score of 9.8, indicating a critical severity with high impact on confidentiality, integrity, and availability. No official patch or remediation details are provided in the available data. There are no known exploits in the wild at this time.
AI Analysis
Technical Summary
CVE-2026-59309 is an authentication bypass vulnerability in VMware vCenter's Directory Service within VMware Cloud Foundation. A remote attacker with network access can exploit this flaw to bypass authentication controls, potentially gaining unauthorized administrative access. The vulnerability is categorized under CWE-303, indicating an incorrect implementation of an authentication algorithm. Affected versions include 5.x, 9.0.x.x, and 9.1.x.x of VMware Cloud Foundation. The CVSS v3.1 base score is 9.8, reflecting network attack vector, no privileges required, no user interaction, and high impact on confidentiality, integrity, and availability. No patch or official fix information is currently available from the vendor or advisory sources.
Potential Impact
Successful exploitation allows an unauthenticated attacker with network access to bypass authentication mechanisms in VMware vCenter, leading to unauthorized full system access. This compromises confidentiality, integrity, and availability of the affected system, potentially allowing control over the VMware Cloud Foundation environment.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until a fix is available, restrict network access to VMware vCenter services to trusted administrators only and monitor for unusual access attempts. Follow VMware's official security advisories for updates on patches or mitigations.
CVE-2026-59309: CWE-303 Incorrect implementation of authentication algorithm in VMware Cloud Foundation
Description
VMware vCenter in Cloud Foundation contains a critical authentication bypass vulnerability in the VMware Directory Service. This flaw allows an attacker with network access to bypass authentication and gain unauthorized access to the system. The vulnerability affects multiple versions of Cloud Foundation, including 5.x, 9.0.x.x, and 9.1.x.x. The vulnerability has a CVSS score of 9.8, indicating a critical severity with high impact on confidentiality, integrity, and availability. No official patch or remediation details are provided in the available data. There are no known exploits in the wild at this time.
CVSS v3.1
Score 9.8critical
Affected software
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2026-59309 is an authentication bypass vulnerability in VMware vCenter's Directory Service within VMware Cloud Foundation. A remote attacker with network access can exploit this flaw to bypass authentication controls, potentially gaining unauthorized administrative access. The vulnerability is categorized under CWE-303, indicating an incorrect implementation of an authentication algorithm. Affected versions include 5.x, 9.0.x.x, and 9.1.x.x of VMware Cloud Foundation. The CVSS v3.1 base score is 9.8, reflecting network attack vector, no privileges required, no user interaction, and high impact on confidentiality, integrity, and availability. No patch or official fix information is currently available from the vendor or advisory sources.
Potential Impact
Successful exploitation allows an unauthenticated attacker with network access to bypass authentication mechanisms in VMware vCenter, leading to unauthorized full system access. This compromises confidentiality, integrity, and availability of the affected system, potentially allowing control over the VMware Cloud Foundation environment.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until a fix is available, restrict network access to VMware vCenter services to trusted administrators only and monitor for unusual access attempts. Follow VMware's official security advisories for updates on patches or mitigations.
Technical Details
- Gcve Source
- db.gcve.eu
- Csaf Category
- csaf_security_advisory
- Csaf Version
- 2.0
- Publisher
- Nationaal Cyber Security Centrum
- Advisory Id
- NCSC-2026-0269
- Cve Count
- 5
- Additional Cves
- ["CVE-2026-59310","CVE-2026-47876","CVE-2026-41703","CVE-2026-41709"]
Threat ID: 6a6ae56a9c2644c7f89bae3c
Added to database: 07/30/2026, 05:47:22 UTC
Last enriched: 08/06/2026, 12:56:49 UTC
Last updated: 09/12/2026, 22:01:35 UTC
Views: 79
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.