Mitsubishi Electric MELSEC iQ-F Series EtherNet/IP module and Ethernet Module (Update A)
Affects CISA Mitsubishi ElectricSource GCVE Database
Not known to be exploited · CVSS 8.7 High.
Data as of 27 Oct 2026, 00:07 UTC
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:NExploitation evidence
Disclosed: evidence found.
CVE published 3 Mar 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| Mitsubishi Electric CorporationMELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP | Affected
| Fixed in– |
| Mitsubishi Electric CorporationMELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP | Affected
| Fixed in– |
Description
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
References
- raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-062-01.json (opens in a new tab)
- mitsubishielectric.com/psirt/vulnerability/pdf/2025-021_en.pdf (opens in a new tab)
- cisa.gov/news-events/ics-advisories/icsa-26-062-01 (opens in a new tab)
- cisa.gov/news-events/ics-alerts/ics-alert-10-301-01 (opens in a new tab)
- cisa.gov/resources-tools/resources/ics-recommended-practices (opens in a new tab)
- cisa.gov/topics/industrial-control-systems (opens in a new tab)
- cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf (opens in a new tab)
- cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf (opens in a new tab)
- cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b (opens in a new tab)