Siemens Engineering Platforms
Affects CISA SiemensSource GCVE Database
Public exploit available · CVSS 7.3 High : upgrade to 5.2.1.1 as a priority.
Data as of 27 Nov 2026, 04:33 UTC
- Patch
- Available – fixed in 5.2.1.1
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:CExploitation evidence
Disclosed: evidence found.
CVE published 10 Dec 2024
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: evidence found.
CVSS exploit maturity: proof of concept public
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), CVSS vector, the Metasploit, Exploit-DB and nuclei-templates index as of 26 Nov 2026.
What to do
Upgrade TIA Portal Cloud V19 to 5.2.1.1.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| SiemensSIMATIC S7-PLCSIM V17 | Affected
| Fixed in– |
| SiemensSIMATIC S7-PLCSIM V18 | Affected
| Fixed in– |
| SiemensSIMATIC STEP 7 Safety V17 | Affected
| Fixed in– |
| SiemensSIMATIC STEP 7 Safety V18 | Affected
| Fixed in– |
| SiemensSIMATIC STEP 7 Safety V19 | Affected
| Fixed in– |
| SiemensSIMATIC STEP 7 V17 | Affected
| Fixed in– |
AI-suggested
Siemens recommends protecting network access to devices with appropriate security mechanisms and configuring the environment according to Siemens' operational guidelines for Industrial Security. Users should follow the recommendations in product manuals and Siemens' published guidelines to maintain security. No patches or fixes are mentioned.
Description
This entry concerns a security recommendation related to Siemens Engineering Platforms. Siemens advises protecting network access to these devices using appropriate security mechanisms and configuring the operational environment according to their Industrial Security guidelines.
References
- cert-portal.siemens.com/productcert/csaf/ssa-392859.json (opens in a new tab)
- cert-portal.siemens.com/productcert/html/ssa-392859.html (opens in a new tab)
- raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-347-02.json (opens in a new tab)
- cisa.gov/news-events/ics-advisories/icsa-24-347-02 (opens in a new tab)
- cisa.gov/news-events/ics-alerts/ics-alert-10-301-01 (opens in a new tab)
- cisa.gov/resources-tools/resources/ics-recommended-practices (opens in a new tab)
- cisa.gov/topics/industrial-control-systems (opens in a new tab)
- cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf (opens in a new tab)
- cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf (opens in a new tab)
- cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b (opens in a new tab)