Siemens Products using OpenSSL
Affects CISA SiemensSource GCVE Database
Not known to be exploited · CVSS 8.8 High · fixed in 3.6.1 : patch CISA Siemens soon.
Data as of 17 Nov 2026, 18:39 UTC
Sources agree
| CISA-ADP | CVSS 3.1 | 8.8 |
|---|---|---|
| ADP (redhat-SADP) | CVSS 3.1 | 9.8 |
- Patch
- Available – fixed in 3.6.1, 3.5.5, 3.4.4 +2
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HExploitation evidence
t = 0 is the CVE’s publication on cve.org
Disclosed: evidence found.
CVE published 27 Jan 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: evidence found.
CISA SSVC: proof of concept public
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
Timeline
CVE ID reserved
by OpenSSL Software Foundation
, 21 days before disclosure
CVE published
on cve.org
, t = 0
CISA SSVC assessment
proof of concept public
, 51 days after disclosure
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), CISA SSVC, the Metasploit, Exploit-DB and nuclei-templates index as of 16 Nov 2026.
What to do
Upgrade to a fixed release listed under Affected software.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| OpenSSLOpenSSL | Affected
| Fixed in
|
| OpenSSLOpenSSL | Affected
| Fixed in
|
| OpenSSLOpenSSL | Affected
| Fixed in
|
| OpenSSLOpenSSL | Affected
| Fixed in
|
| OpenSSLOpenSSL | Affected
| Fixed in
|
AI-suggested
Siemens recommends protecting network access to devices using appropriate security mechanisms and operating the devices within a protected IT environment configured according to Siemens' operational guidelines for Industrial Security and product manuals. No specific patches or fixes are mentioned. Users should follow Siemens' official guidelines for securing their industrial devices.
Description
This entry concerns Siemens products that use OpenSSL and highlights a general security recommendation from Siemens to protect network access to these devices. Siemens advises operating the devices within a protected IT environment following their operational guidelines for Industrial Security and product manuals.
References
- cert-portal.siemens.com/productcert/csaf/ssa-434797.json (opens in a new tab)
- cert-portal.siemens.com/productcert/html/ssa-434797.html (opens in a new tab)
- raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-174-03.json (opens in a new tab)
- cisa.gov/news-events/ics-advisories/icsa-26-174-03 (opens in a new tab)
- cisa.gov/news-events/ics-alerts/ics-alert-10-301-01 (opens in a new tab)
- cisa.gov/resources-tools/resources/ics-recommended-practices (opens in a new tab)
- cisa.gov/topics/industrial-control-systems (opens in a new tab)
- cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf (opens in a new tab)
- cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf (opens in a new tab)
- cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b (opens in a new tab)