Simcenter Femap · SSA-105852: Out of Bounds Read Vulnerability
Affects SiemensSource GCVE Database
Not known to be exploited · CVSS 7.8 High · fixed in 38.0.235 : patch Siemens soon.
Data as of 10 Nov 2026, 13:32 UTC
Thin evidence
One scorer or none| CNA (siemens) | CVSS 3.1 | 7.8 |
|---|---|---|
| CNA (siemens) | CVSS 4.0 | 7.3 |
- Patch
- Available – fixed in 38.0.235, 38.1.230, 2606.0002
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HExploitation evidence
Disclosed: evidence found.
CVE published 11 Aug 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 10 Nov 2026.
What to do
Upgrade Parasolid V38.0 to 38.0.235; Parasolid V38.1 to 38.1.230; Simcenter Femap to 2606.0002.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| SiemensParasolid V38.0 | Affected
| Fixed in
|
| SiemensParasolid V38.1 | Affected
| Fixed in
|
| SiemensSimcenter Femap | Affected
| Fixed in
|
AI-suggested
Siemens recommends protecting network access to devices with appropriate mechanisms and configuring the environment according to Siemens' operational guidelines for Industrial Security.
Description
An out-of-bounds read vulnerability (CWE-125) has been identified in Siemens Simcenter Femap. Siemens recommends protecting network access to affected devices using appropriate security mechanisms and following their operational guidelines for Industrial Security.