The Guardian 2 alarm unit lacks a mechanism to authenticate control commands sent over 433.92 MHz, which allows an
Source GCVE Database
Not known to be exploited · CVSS 7.1 High.
Data as of 19 Nov 2026, 13:50 UTC
Thin evidence
One scorer or none| CNA (ENISA) | CVSS 4.0 | 7.1 |
|---|
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:NExploitation evidence
Disclosed: evidence found.
CVE published 19 Nov 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 18 Nov 2026.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| Onyx Cookware ApSNexsmart Guardian 2 (Alarm system) | Affected
| Fixed in– |
AI-suggested
Users should be aware of the risk of replay attacks on the Guardian 2 alarm unit and consider additional physical security measures or alternative alarm systems that implement command authentication. Monitor vendor advisories for any future updates or patches.
Description
The Guardian 2 alarm unit does not authenticate control commands sent over the 433.92 MHz frequency, allowing attackers to replay static commands. This vulnerability enables an attacker to impersonate legitimate activity and potentially arm or disarm the system if a Nexsmart keypad is used, fully compromising the alarm system's functionality.