Skip to main content
Report · Zero Day InitiativeAbout CVE-2026-18278Published

ZDI-26-471: (Pwn2Own) Sony XAV-9500ES prh_l2_decode_packet Out-Of-Bounds Read Information Disclosure Vulnerability

Source Zero Day Initiative

0
Compare
Authoritative record:CVE-2026-18278· Low 3.5

Not known to be exploited · CVSS 3.5 Low.

Data as of 5 Nov 2026, 23:24 UTC

CVSS 3.0 base score
3.5Low
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 15% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 20 Aug 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 6 Nov 2026.

What to do

Affected software

ProductAffectedFixed in
SonyXAV-9500ESAffected
  • =3.02.0.0
Fixed in–

AI-suggested

Sony has issued an official update to correct this vulnerability. Users of the Sony XAV-9500ES device should apply the provided update available at Sony's support page: https://www.sony.com/electronics/support/mobile-cd-players-digital-media-players-xav-series/xav-9500es/software/00274922. Applying this update mitigates the vulnerability. No additional mitigations are specified or required.

Description

Sony XAV-9500ES prh_l2_decode_packet Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Sony XAV-9500ES devices. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability. The specific flaw exists within the handling of Bluetooth L2CAP packets. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-28990.

References

Community reviews

Loading reviews…