Nexxt Solutions Nebula 300+ firmware through version 12.01.01.37 uses the ecos_pw cookie for authentication, which contains Base64-encoded credential data combined with a static suffix. Because the encoding is reversible and lacks integrity protection, an attacker can reconstruct or forge a valid cookie value without proper authentication.
Edimax GS-5008PL firmware version 1.00.54 and prior contain an insecure credential storage vulnerability that allows attackers to obtain administrator credentials by accessing configuration backup files. Attackers can download the config.bin file through fupload.cgi to extract plaintext username and password fields for unauthorized administrative access.
The SAP Customer Checkout application exhibits certain design characteristics that involve locally storing operational data using reversible protection mechanisms. Access to this data, combined with user?initiated interaction, may allow modifications to occur without validation. Such changes could affect system behaviour during startup, resulting in a high impact on the application's confidentiality and integrity, with a low impact on availability.
Cleartext Storage of Sensitive Information (CWE-312) in the Command Centre Mobile Client on Android and iOS could allow an attacker with access to a logged-in Operator's mobile device to extract the session token and exploit access for a limited duration.
This issue affects Command Centre Mobile Client versions prior to 9.40.123.
The OpenID Connect (OIDC) authentication configuration in PowerShell
Universal before 2026.1.3 stores the OIDC client secret in cleartext in
the .universal/authentication.ps1 script, which allows an attacker with read access to that file to obtain the OIDC client credentials
Sensitive
user account information is not encrypted in the database in Devolutions Server 2025.3.14 and earlier, which allows an attacker with
access to the database to obtain sensitive user
information via direct database access.
Binardat 10G08-0800GSM network switch firmware versions prior to V300SP10260209 store a user password in a client-side cookie as a Base64-encoded value accessible via the web interface. Because Base64 is reversible and provides no confidentiality, an attacker who can access the cookie value can recover the plaintext password.
Insecure Storage of Sensitive Information vulnerability in Birtech Information Technologies Industry and Trade Ltd. Co. Senseway allows Retrieve Embedded Sensitive Data.
This issue affects Senseway: through 09022026.
NOTE: Because the product was developed using outdated technology, the manufacturer is unable to fix the relevant vulnerabilities. Users of the Sensaway application are advised to contact the manufacturer and review updated products developed with newer technology.
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. An information disclosure vulnerability in FUXA allows an unauthenticated, remote attacker to retrieve sensitive administrative database credentials. Exploitation allows an unauthenticated, remote attacker to obtain the full system configuration, including administrative credentials for the InfluxDB database. Possession of these credentials may allow an attacker to authenticate directly to the database service, enabling them to read, modify, or delete all historical process data, or perform a Denial of Service by corrupting the database. This affects FUXA through version 1.2.9. This issue has been patched in FUXA version 1.2.10.
CVE-2025-12774 is a medium severity vulnerability in Brocade SANnav versions before 3.0 involving cleartext storage of sensitive information within the SANnav support save file. The issue arises from a migration script that collects database SQL queries and stores them in the support save file, which can be accessed by an attacker with file access. This exposure could reveal sensitive details such as database table structures and encrypted passwords. Exploitation requires local access to the support save file and high privileges on the system, with no user interaction needed. While no known exploits are currently reported in the wild, the vulnerability poses a risk to confidentiality if the support save file is improperly handled or accessed by unauthorized users. European organizations using Brocade SANnav for storage area network management should be aware of this risk and implement strict access controls and update to version 3.0 or later when available.
Brocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs.
When OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password.
A vulnerability in Brocade SANnav before 2.4.0b prints the
Password-Based Encryption (PBE) key in plaintext in the system audit log
file. The vulnerability could allow a remote authenticated attacker
with access to the audit logs to access the pbe key.
Note: The vulnerability is only triggered during a migration and not
in a new installation. The system audit logs are accessible only to a
privileged user on the server.
These audit logs are the local server VM’s audit logs and are not
controlled by SANnav. These logs are only visible to the server admin of
the host server and are not visible to the SANnav admin or any SANnav
user.
CVE-2025-12680 is a medium-severity vulnerability affecting Brocade SANnav versions prior to 2.4.0b, where database passwords are stored in plaintext within logs on the standby SANnav server after disaster recovery failover. This flaw allows a remote attacker with administrative privileges and some user interaction to access sensitive logs or supportsave files and extract database credentials. Exploitation requires authenticated admin access but can lead to credential compromise, potentially enabling further unauthorized access to SANnav-managed storage infrastructure. No known exploits are currently reported in the wild. The vulnerability impacts confidentiality primarily, with a CVSS score of 6. European organizations using affected Brocade SANnav versions should prioritize patching and restrict access to logs and supportsave files. Countries with significant enterprise storage deployments and Brocade SANnav usage, such as Germany, France, and the UK, are most likely to be affected.
With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database.
The web server of the Access Manager offers a functionality to download a backup of the local database stored on the device. This database contains the whole configuration. This includes encrypted MIFARE keys, card data, user PINs and much more. The PINs are even stored unencrypted. Combined with the fact that an attacker can easily get access to the backup functionality by abusing the session management issue (CVE-2025-59101), or by exploiting the weak default password (CVE-2025-59108), or by simply setting a new password without prior authentication via the SOAP API (CVE-2025-59097), it is easily possible to access the sensitive data on the device.
CVE-2026-22276 is a medium severity vulnerability affecting Dell ObjectScale and Dell ECS versions prior to 4.2.0.0 and 3.8.1.8 respectively. It involves the cleartext storage of sensitive information, allowing a low-privileged local attacker to potentially disclose confidential data without requiring user interaction. The vulnerability does not impact integrity or availability but poses a confidentiality risk. Exploitation requires local access and low privileges, limiting remote attack feasibility.
A security issue was discovered within the legacy Ansible playbook component of Verve Asset Manager, caused by plaintext secrets incorrectly stored when a playbook is running. This component has been retired and has been optional since the 1.36 release in 2024.