A security flaw has been discovered in Edimax BR-6428NS 1.10. This affects the function formWirelessTbl of the file /goform/formWirelessTbl of the component POST Request Handler. Performing a manipulation of the argument vapurl results in buffer overflow. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was identified in Edimax BR-6428NS 1.10. The impacted element is the function formWanTcpipSetup of the file /goform/formWanTcpipSetup of the component POST Request Handler. Such manipulation of the argument pppUserName leads to buffer overflow. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Edimax BR-6428NS 1.10. This issue affects the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component POST Request Handler. Performing a manipulation of the argument stadrv_ssid results in command injection. The attack can be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-8776 is a high-severity buffer overflow vulnerability in the Edimax BR-6428NS router version 1.10. It affects the formPPTPSetup function handling POST requests, where manipulation of the pptpUserName argument can cause a buffer overflow. The vulnerability can be exploited remotely without user interaction and has been publicly disclosed. The vendor has not responded or provided a patch or mitigation guidance. No known exploits are currently reported in the wild.
CVE-2026-8775 is a high-severity buffer overflow vulnerability in the Edimax BR-6428NS router version 1.10. The flaw exists in the formL2TPSetup function handling the POST request at /goform/formL2TPSetup, where manipulation of the L2TPUserName parameter can trigger a buffer overflow. This vulnerability can be exploited remotely without user interaction or privileges. Although the exploit code has been published, there is no known exploit activity in the wild. The vendor has not responded or provided a patch or mitigation guidance.
A vulnerability was detected in Edimax BR-6228NC 1.22. Affected by this issue is the function mp of the file /goform/mp of the component POST Request Handler. The manipulation of the argument command results in command injection. The attack may be performed from remote. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-7685 is a high-severity buffer overflow vulnerability in the Edimax BR-6208AC router firmware version 1.02. The flaw exists in an unknown function within the /goform/setWAN file, where manipulation of the pptpDfGateway argument can trigger the overflow. This vulnerability can be exploited remotely without user interaction or privileges. Although the exploit code is publicly available, there is no known exploit activity in the wild. The vendor has not responded or provided a patch or mitigation guidance as of the publication date.
CVE-2026-7684 is a high-severity buffer overflow vulnerability in the Edimax BR-6428nC router firmware versions up to 1.16. The flaw exists in an unspecified function within the /goform/setWAN file, where manipulation of the pptpDfGateway argument can trigger the overflow. This vulnerability can be exploited remotely without user interaction or privileges. The vendor has not responded to disclosure attempts, and no patch or official remediation is currently available. Although the exploit has been publicly disclosed, there are no confirmed reports of exploitation in the wild.
CVE-2026-7683 is a command injection vulnerability in the Edimax BR-6428nC router models up to firmware version 1.16. The flaw exists in the web interface component, specifically in the /goform/setWAN endpoint, where manipulation of the pppUserName or pptpUserName parameters can lead to command injection. This vulnerability can be exploited remotely without user interaction. The vendor has not responded to disclosure requests, and no official patch or remediation guidance is currently available. The CVSS 4.0 base score is 5.3, indicating a medium severity level.
A security flaw has been discovered in Edimax BR-6208AC 1.02. The impacted element is the function setWAN of the file /goform/setWAN of the component L2TP Mode. The manipulation of the argument L2TPUserName results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Edimax GS-5008PL firmware version 1.00.54 and prior use cleartext HTTP for the web management interface without implementing TLS or SSL encryption. Attackers on the same network can intercept management traffic to capture administrator credentials and sensitive configuration data.
Edimax GS-5008PL firmware version 1.00.54 and prior contain a cross-site request forgery vulnerability that allows remote attackers to perform unauthorized administrative actions by inducing logged-in administrators to visit malicious pages. Attackers can exploit the lack of anti-CSRF tokens and request validation to change passwords, upload firmware, reboot the device, perform factory resets, or modify network configurations.
Edimax GS-5008PL firmware version 1.00.54 and prior contain a stored cross-site scripting vulnerability in the system_name_set.cgi script that allows attackers to inject arbitrary script code by manipulating the sysName parameter. Attackers can send a crafted POST request with malicious script payload that executes when management pages including system_data.js are viewed by administrators.
Edimax GS-5008PL firmware version 1.00.54 and prior contain an insecure credential storage vulnerability that allows attackers to obtain administrator credentials by accessing configuration backup files. Attackers can download the config.bin file through fupload.cgi to extract plaintext username and password fields for unauthorized administrative access.
Edimax GS-5008PL firmware versions 1.00.54 and prior contain an authentication bypass vulnerability that allows unauthenticated attackers to access the management interface. Attackers can exploit the global authentication flag mechanism to gain administrative access without credentials after any user authenticates, enabling unauthorized password changes, firmware uploads, and configuration modifications.
A vulnerability was found in Edimax BR-6208AC 2_1.02. The affected element is the function auth_check_userpass2. Performing a manipulation of the argument Username/Password results in use of default credentials. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability has been found in Edimax BR-6288ACL up to 1.12. Impacted is the function wiz_WISP24gmanual of the file wiz_WISP24gmanual.asp. Such manipulation of the argument manualssid leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer.
A flaw has been found in Edimax BR-6258n up to 1.18. This issue affects the function formStaDrvSetup of the file /goform/formStaDrvSetup. This manipulation of the argument submit-url causes open redirect. The attack can be initiated remotely. The exploit has been published and may be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer.
A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.
A security flaw has been discovered in Edimax BR-6208AC 1.02/1.03. Affected by this vulnerability is the function formRoute of the file /gogorm/formRoute of the component Web-based Configuration Interface. The manipulation of the argument strIp/strMask/strGateway results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.