A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside… (CVE-2026-19003)
A vulnerability in the MongoDB BI Connector ODBC Driver setup dialog can cause a buffer overflow when handling an over-length file path in a data source definition. This occurs due to incorrect buffer capacity calculation during file or folder selection in the setup dialog. The issue is triggered only when a user opens the setup dialog and initiates file or folder selection for such a data source. The impact ranges from abnormal termination of the process to potential execution of unintended code with the user's privileges.
AI Analysis
Technical Summary
CVE-2026-19003 describes a buffer overflow vulnerability in the MongoDB BI Connector ODBC Driver setup dialog. The flaw arises from improper calculation of buffer capacity when processing over-length file path settings in data source definitions. This vulnerability is exploitable when a user opens the setup dialog and performs file or folder selection, leading to writes outside the allocated buffer. Depending on the build configuration, this can cause process crashes or, under certain conditions, arbitrary code execution in the context of the user running the dialog. The vulnerability is classified under CWE-121 (Stack-based Buffer Overflow) and has a CVSS 3.1 score of 7.8, indicating high severity.
Potential Impact
Successful exploitation can lead to high impact outcomes including confidentiality, integrity, and availability compromises. Specifically, it may cause abnormal termination of the setup dialog process or execution of arbitrary code with the privileges of the user running the dialog, potentially allowing unauthorized actions within that user context.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, users should avoid opening the MongoDB BI Connector ODBC Driver setup dialog for data sources containing over-length file path settings to prevent triggering the vulnerability.
A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside… (CVE-2026-19003)
Description
A vulnerability in the MongoDB BI Connector ODBC Driver setup dialog can cause a buffer overflow when handling an over-length file path in a data source definition. This occurs due to incorrect buffer capacity calculation during file or folder selection in the setup dialog. The issue is triggered only when a user opens the setup dialog and initiates file or folder selection for such a data source. The impact ranges from abnormal termination of the process to potential execution of unintended code with the user's privileges.
CVSS v3.1
Score 7.8high
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2026-19003 describes a buffer overflow vulnerability in the MongoDB BI Connector ODBC Driver setup dialog. The flaw arises from improper calculation of buffer capacity when processing over-length file path settings in data source definitions. This vulnerability is exploitable when a user opens the setup dialog and performs file or folder selection, leading to writes outside the allocated buffer. Depending on the build configuration, this can cause process crashes or, under certain conditions, arbitrary code execution in the context of the user running the dialog. The vulnerability is classified under CWE-121 (Stack-based Buffer Overflow) and has a CVSS 3.1 score of 7.8, indicating high severity.
Potential Impact
Successful exploitation can lead to high impact outcomes including confidentiality, integrity, and availability compromises. Specifically, it may cause abnormal termination of the setup dialog process or execution of arbitrary code with the privileges of the user running the dialog, potentially allowing unauthorized actions within that user context.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, users should avoid opening the MongoDB BI Connector ODBC Driver setup dialog for data sources containing over-length file path settings to prevent triggering the vulnerability.
Technical Details
- Gcve Source
- db.gcve.eu
- Osv Id
- GHSA-5vfq-q6f3-hh9v
- Osv Schema Version
- 1.4.0
- Aliases
- ["CVE-2026-19003"]
- Ecosystems
- []
- Database Specific Severity
- HIGH
- Cvss Version
- 3.1
Threat ID: 6a7d12d2bf8831d5396c18e3
Added to database: 08/13/2026, 00:41:54 UTC
Last enriched: 08/13/2026, 00:56:07 UTC
Last updated: 08/13/2026, 03:41:00 UTC
Views: 6
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.