Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.3). (CVE-2026-69109)

0
High
Published: 08/11/2026 (08/11/2026, 15:32:37 UTC)
Source: GCVE Database

Description

Siemens License Server (SLS) versions prior to 5.3 contain a path traversal vulnerability due to insufficient sanitization of user input. This flaw allows remote attackers to access arbitrary files on the system. The vulnerability has a high severity score of 7.5 and does not require user interaction or privileges to exploit.

CVSS v3.1

Score 7.5high

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Affected software

Affected versions
<5.3

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 08/11/2026, 19:00:12 UTC

Technical Analysis

CVE-2026-69109 identifies a path traversal vulnerability in Siemens License Server (SLS) affecting all versions before 5.3. The vulnerability arises from improper sanitization of user-supplied input, enabling remote attackers to read arbitrary files on the server. The CVSS 3.1 base score is 7.5, reflecting high impact on confidentiality with no impact on integrity or availability. There are no known exploits in the wild and no official patch or remediation information is currently provided.

Potential Impact

Successful exploitation allows an unauthenticated remote attacker to read arbitrary files on the affected system, potentially exposing sensitive information. There is no impact on system integrity or availability according to the CVSS vector. This could lead to information disclosure but not direct system compromise or denial of service.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict network access to the Siemens License Server and monitor for suspicious activity related to file access attempts. Avoid exposing the service to untrusted networks.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Gcve Source
db.gcve.eu
Osv Id
GHSA-g4jx-hhxc-5329
Osv Schema Version
1.4.0
Aliases
["CVE-2026-69109"]
Ecosystems
[]
Database Specific Severity
HIGH
Cvss Version
3.1

Threat ID: 6a7b6fd0bf8831d5393ea173

Added to database: 08/11/2026, 18:54:08 UTC

Last enriched: 08/11/2026, 19:00:12 UTC

Last updated: 08/12/2026, 02:40:59 UTC

Views: 3

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses