Skip to main content

CVE-2021-37183: CWE-284: Improper Access Control in Siemens SINEMA Remote Connect Server

Medium
Published: Tue Sep 14 2021 (09/14/2021, 10:47:47 UTC)
Source: CVE
Vendor/Project: Siemens
Product: SINEMA Remote Connect Server

Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software allows sending send-to-sleep notifications to the managed devices. An unauthenticated attacker in the same network of the affected system can abuse these notifications to cause a Denial-of-Service condition in the managed devices.

AI-Powered Analysis

AILast updated: 06/23/2025, 22:12:40 UTC

Technical Analysis

CVE-2021-37183 is a vulnerability classified under CWE-284 (Improper Access Control) affecting Siemens SINEMA Remote Connect Server versions prior to 3.0 SP2. The SINEMA Remote Connect Server is used to manage remote devices, typically in industrial and critical infrastructure environments, enabling secure remote access and management. The vulnerability arises from the server's handling of "send-to-sleep" notifications, which are commands intended to put managed devices into a low-power or sleep state. Due to insufficient access control, an unauthenticated attacker who is on the same network segment as the vulnerable server can send these notifications to managed devices without any authentication or authorization checks. This can cause a Denial-of-Service (DoS) condition by forcing devices to enter sleep mode unexpectedly, disrupting their normal operation. The vulnerability does not impact confidentiality or integrity directly but severely affects availability. The CVSS 3.1 base score is 6.5 (medium severity), reflecting that the attack vector is adjacent network (AV:A), requires no privileges (PR:N), no user interaction (UI:N), and impacts availability only (A:H). No known exploits have been reported in the wild, but the ease of exploitation within the same network and the critical nature of affected devices make this a significant concern, especially in industrial control systems (ICS) and operational technology (OT) environments where SINEMA Remote Connect Server is deployed. Siemens has not provided patch links in the provided data, but the fixed version is 3.0 SP2 and later.

Potential Impact

For European organizations, especially those operating in industrial sectors such as manufacturing, energy, utilities, transportation, and critical infrastructure, this vulnerability poses a risk of operational disruption. The ability of an unauthenticated attacker to cause managed devices to enter sleep mode can halt production lines, disrupt energy distribution, or impair transportation control systems, leading to financial losses, safety risks, and regulatory non-compliance. Since SINEMA Remote Connect Server is designed for remote management of critical devices, the availability impact can cascade, affecting multiple systems managed by the server. The requirement for the attacker to be on the same network limits remote exploitation but does not eliminate risk, as insider threats or lateral movement after initial compromise could enable exploitation. European organizations with segmented networks and strict access controls may reduce risk, but those with less mature network segmentation or remote access policies are more vulnerable. The lack of confidentiality and integrity impact reduces the risk of data breaches but does not mitigate the operational impact of service disruption.

Mitigation Recommendations

1. Upgrade SINEMA Remote Connect Server to version 3.0 SP2 or later, where the vulnerability is fixed. 2. Implement strict network segmentation to isolate SINEMA Remote Connect Server and managed devices from general user networks, limiting attacker access to the same network segment. 3. Enforce strong access control policies and monitor network traffic for anomalous "send-to-sleep" notification packets or unusual device sleep commands. 4. Deploy intrusion detection/prevention systems (IDS/IPS) with signatures or heuristics to detect exploitation attempts targeting this vulnerability. 5. Conduct regular security audits and penetration tests focusing on network access controls around OT and ICS environments. 6. Educate operational staff about the risks of lateral movement and insider threats, ensuring that network access is tightly controlled and monitored. 7. If possible, implement additional authentication or validation mechanisms on the management commands sent to devices, either through configuration or compensating controls. 8. Maintain up-to-date asset inventories to quickly identify affected SINEMA Remote Connect Server instances and managed devices.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2021-07-21T00:00:00.000Z
Cisa Enriched
true

Threat ID: 682d9841c4522896dcbf1c22

Added to database: 5/21/2025, 9:09:21 AM

Last enriched: 6/23/2025, 10:12:40 PM

Last updated: 8/11/2025, 5:24:25 AM

Views: 14

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.