Skip to main content
VulnerabilityPublished Updated

CVE-2024-22813: Use of Hard-coded Credentials

Source CVE Database V5

0

Not known to be exploited · CVSS 4.4 Medium.

Data as of 26 Oct 2026, 17:16 UTC

CVSS 3.1 base score
4.4Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.3% chance of exploitation in 30 days – higher than 32% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 22 Apr 2024

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

AI-suggested

To mitigate CVE-2024-22813, organizations should implement strict access controls to limit administrative privileges on the Tormach xsTECH CNC Router and PathPilot Controller devices. Network segmentation should be employed to isolate CNC equipment from general IT networks, reducing the attack surface. Monitoring network traffic for unusual IP address changes or connectivity disruptions can provide early detection of exploitation attempts. Since no patches are currently available, organizations should engage with the vendor for updates and apply them promptly once released. Additionally, implementing multi-factor authentication for device management interfaces can reduce the risk of unauthorized access. Regular audits of device configurations and memory contents may help identify unauthorized modifications. Backup and recovery procedures should be established to quickly restore device configurations if disruption occurs. Finally, educating staff about the importance of securing industrial control systems can help prevent privilege escalation scenarios that enable exploitation.

Description

An issue in Tormach xsTECH CNC Router, PathPilot Controller v2.9.6 allows attackers to overwrite the hardcoded IP address in the device memory, disrupting network connectivity between the router and the controller.