Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2024-32407: n/a

0
High
VulnerabilityCVE-2024-32407cvecve-2024-32407
Published: Mon Apr 22 2024 (04/22/2024, 00:00:00 UTC)
Source: CVE Database V5

Description

CVE-2024-32407 is a high-severity remote code execution vulnerability in the Page Sandbox feature of the Inducer Relate software before version 2024. 1. It allows an attacker with low privileges and no user interaction to execute arbitrary code remotely by sending a crafted payload. The vulnerability is classified under CWE-918, indicating improper control of dynamically loaded code. Although no known exploits are currently in the wild, the CVSS score of 8. 8 reflects the critical impact on confidentiality, integrity, and availability. This flaw could enable attackers to fully compromise affected systems. No official patches have been released yet, increasing the urgency for mitigation. Organizations using Inducer Relate should monitor for updates and apply strict network controls to limit exposure. Countries with significant usage of this software and critical infrastructure relying on it are at higher risk.

AI-Powered Analysis

AILast updated: 02/26/2026, 04:20:23 UTC

Technical Analysis

CVE-2024-32407 is a vulnerability identified in the Inducer Relate software, specifically affecting versions prior to 2024.1. The flaw resides in the Page Sandbox feature, which is intended to isolate and securely execute code. However, due to improper handling of dynamically loaded code (CWE-918), a remote attacker can craft a malicious payload that bypasses sandbox restrictions and executes arbitrary code on the target system. The attack vector requires network access and low privileges but does not require user interaction, making it easier to exploit remotely. The vulnerability impacts confidentiality, integrity, and availability, as attackers can potentially take full control of the affected system. The CVSS v3.1 score of 8.8 reflects this high severity, with an attack vector of network (AV:N), low attack complexity (AC:L), privileges required (PR:L), no user interaction (UI:N), and unchanged scope (S:U). No patches or mitigations have been officially released at the time of publication, and no active exploits have been reported. This vulnerability demands urgent attention from organizations using Inducer Relate to prevent future exploitation.

Potential Impact

The impact of CVE-2024-32407 is significant for organizations worldwide using Inducer Relate software. Successful exploitation allows remote attackers to execute arbitrary code, potentially leading to full system compromise. This can result in data breaches, unauthorized access to sensitive information, disruption of services, and potential lateral movement within networks. The vulnerability affects confidentiality, integrity, and availability, making it a critical risk for environments where Inducer Relate is deployed, especially in sectors like finance, healthcare, government, and critical infrastructure. The lack of user interaction requirement and low attack complexity increase the likelihood of exploitation once exploit code becomes available. Organizations may face operational downtime, reputational damage, and regulatory penalties if exploited.

Mitigation Recommendations

Until an official patch is released, organizations should implement the following mitigations: 1) Restrict network access to the Inducer Relate service using firewalls and network segmentation to limit exposure to trusted sources only. 2) Monitor network traffic and logs for unusual or suspicious activity related to the Page Sandbox feature. 3) Employ application-layer firewalls or intrusion detection/prevention systems (IDS/IPS) with updated signatures to detect attempts to exploit this vulnerability. 4) Conduct thorough privilege audits and minimize privileges for users and services interacting with Inducer Relate to reduce the impact of potential exploitation. 5) Prepare for rapid deployment of patches once available by maintaining an up-to-date asset inventory and patch management process. 6) Engage with the vendor for timely updates and guidance. 7) Consider temporary disabling or restricting the Page Sandbox feature if feasible without impacting critical operations.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.1
Assigner Short Name
mitre
Date Reserved
2024-04-12T00:00:00.000Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 699f6c37b7ef31ef0b56138b

Added to database: 2/25/2026, 9:40:07 PM

Last enriched: 2/26/2026, 4:20:23 AM

Last updated: 2/26/2026, 6:12:28 AM

Views: 1

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats