Technical Summary
CVE-2024-35659 identifies a missing authorization vulnerability in the KiviCare clinic management system developed by Iqonic Design, affecting all versions up to and including 3.6.6. The vulnerability arises from incorrectly configured access control security levels, which means that certain functions or data within the system can be accessed without proper authorization checks. This flaw can be exploited by an attacker who gains access to the system interface to perform actions or retrieve information that should be restricted. The vulnerability does not require a known exploit in the wild yet, but its presence in a healthcare management system is concerning due to the sensitive nature of patient and clinic data handled by KiviCare. The lack of a CVSS score indicates that the vulnerability is newly disclosed and not yet fully assessed, but the missing authorization issue typically represents a critical security weakness. The vulnerability affects the confidentiality and integrity of data, as unauthorized users could view or modify sensitive information. The ease of exploitation depends on the attacker's ability to reach the vulnerable interface, but no user interaction or complex authentication bypass is explicitly required. The scope includes all installations of KiviCare up to version 3.6.6, which may be deployed in various healthcare organizations worldwide. The absence of patch links suggests that a fix may still be pending or in development, emphasizing the need for immediate mitigation measures.
Potential Impact
The impact of CVE-2024-35659 on organizations worldwide, particularly healthcare providers using KiviCare, can be significant. Unauthorized access to clinic management systems can lead to exposure of sensitive patient data, including personal health information (PHI), appointment details, billing information, and medical records. This can result in privacy violations, regulatory non-compliance (e.g., HIPAA, GDPR), and reputational damage. Additionally, unauthorized modification of clinic data could disrupt healthcare operations, leading to incorrect treatments, scheduling errors, or financial fraud. The vulnerability could also be leveraged as a foothold for further attacks within the healthcare network. Given the critical nature of healthcare services, any disruption or data breach can have severe consequences for patient safety and organizational trust. The lack of known exploits in the wild reduces immediate risk but does not eliminate the potential for targeted attacks, especially as threat actors often prioritize healthcare systems. Organizations with limited security controls or exposed KiviCare instances are at higher risk of exploitation.
Mitigation Recommendations
To mitigate CVE-2024-35659, organizations should take the following specific actions: 1) Immediately audit and review all access control configurations within KiviCare to ensure that security levels are correctly set and that no unauthorized access is possible. 2) Restrict network access to the KiviCare management interface by implementing network segmentation, firewalls, and VPNs to limit exposure to trusted users only. 3) Monitor logs and user activity for unusual access patterns or attempts to access restricted functions. 4) Engage with Iqonic Design to obtain or inquire about patches or updates addressing this vulnerability and apply them promptly once available. 5) Implement multi-factor authentication (MFA) for all users accessing the system to add an additional layer of security. 6) Educate staff about the risks of unauthorized access and enforce strict user privilege management, granting the least privilege necessary. 7) Consider deploying web application firewalls (WAFs) to detect and block suspicious requests targeting access control weaknesses. 8) Regularly back up critical data and verify recovery procedures to minimize impact in case of data tampering or loss. These steps go beyond generic advice by focusing on configuration audits, network controls, and proactive monitoring tailored to the specific vulnerability context.
Affected Countries
United States, India, United Kingdom, Canada, Australia, Germany, France, Brazil, South Africa, United Arab Emirates
CVE-2024-35659: Missing Authorization in Iqonic Design KiviCare
Description
Missing Authorization vulnerability in Iqonic Design KiviCare kivicare-clinic-management-system allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects KiviCare: from n/a through <= 3.6.6.
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2024-35659 identifies a missing authorization vulnerability in the KiviCare clinic management system developed by Iqonic Design, affecting all versions up to and including 3.6.6. The vulnerability arises from incorrectly configured access control security levels, which means that certain functions or data within the system can be accessed without proper authorization checks. This flaw can be exploited by an attacker who gains access to the system interface to perform actions or retrieve information that should be restricted. The vulnerability does not require a known exploit in the wild yet, but its presence in a healthcare management system is concerning due to the sensitive nature of patient and clinic data handled by KiviCare. The lack of a CVSS score indicates that the vulnerability is newly disclosed and not yet fully assessed, but the missing authorization issue typically represents a critical security weakness. The vulnerability affects the confidentiality and integrity of data, as unauthorized users could view or modify sensitive information. The ease of exploitation depends on the attacker's ability to reach the vulnerable interface, but no user interaction or complex authentication bypass is explicitly required. The scope includes all installations of KiviCare up to version 3.6.6, which may be deployed in various healthcare organizations worldwide. The absence of patch links suggests that a fix may still be pending or in development, emphasizing the need for immediate mitigation measures.
Potential Impact
The impact of CVE-2024-35659 on organizations worldwide, particularly healthcare providers using KiviCare, can be significant. Unauthorized access to clinic management systems can lead to exposure of sensitive patient data, including personal health information (PHI), appointment details, billing information, and medical records. This can result in privacy violations, regulatory non-compliance (e.g., HIPAA, GDPR), and reputational damage. Additionally, unauthorized modification of clinic data could disrupt healthcare operations, leading to incorrect treatments, scheduling errors, or financial fraud. The vulnerability could also be leveraged as a foothold for further attacks within the healthcare network. Given the critical nature of healthcare services, any disruption or data breach can have severe consequences for patient safety and organizational trust. The lack of known exploits in the wild reduces immediate risk but does not eliminate the potential for targeted attacks, especially as threat actors often prioritize healthcare systems. Organizations with limited security controls or exposed KiviCare instances are at higher risk of exploitation.
Mitigation Recommendations
To mitigate CVE-2024-35659, organizations should take the following specific actions: 1) Immediately audit and review all access control configurations within KiviCare to ensure that security levels are correctly set and that no unauthorized access is possible. 2) Restrict network access to the KiviCare management interface by implementing network segmentation, firewalls, and VPNs to limit exposure to trusted users only. 3) Monitor logs and user activity for unusual access patterns or attempts to access restricted functions. 4) Engage with Iqonic Design to obtain or inquire about patches or updates addressing this vulnerability and apply them promptly once available. 5) Implement multi-factor authentication (MFA) for all users accessing the system to add an additional layer of security. 6) Educate staff about the risks of unauthorized access and enforce strict user privilege management, granting the least privilege necessary. 7) Consider deploying web application firewalls (WAFs) to detect and block suspicious requests targeting access control weaknesses. 8) Regularly back up critical data and verify recovery procedures to minimize impact in case of data tampering or loss. These steps go beyond generic advice by focusing on configuration audits, network controls, and proactive monitoring tailored to the specific vulnerability context.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- Patchstack
- Date Reserved
- 2024-05-17T10:08:24.113Z
- Cvss Version
- null
- State
- PUBLISHED
Threat ID: 69cd743ce6bfc5ba1def66a1
Added to database: 4/1/2026, 7:38:36 PM
Last enriched: 4/2/2026, 4:54:01 AM
Last updated: 4/4/2026, 8:24:26 AM
Views: 3
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.