CVE-2025-0152: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in IBM Engineering Requirements Management DOORS and DOORS Web Access
IBM Engineering Requirements Management DOORS and DOORS Web Access 9.7.2.1 through 9.7.2.11, and 9.6.1.1 through 9.6.1.13 is vulnerable to cross-site scripting. This vulnerability allows an unauthenticated attacker to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session.
AI Analysis
Technical Summary
CVE-2025-0152 is a cross-site scripting vulnerability (CWE-79) affecting IBM Engineering Requirements Management DOORS and DOORS Web Access versions 9.7.2.1 through 9.7.2.11 and 9.6.1.1 through 9.6.1.13. The vulnerability enables unauthenticated attackers to embed arbitrary JavaScript code in the web UI, which can alter intended functionality and potentially disclose credentials within a trusted session. The CVSS 3.1 base score is 6.1, reflecting network attack vector, low attack complexity, no privileges required, user interaction required, scope change, and low impact on confidentiality and integrity with no impact on availability. No vendor advisory or patch information is currently available, and no known exploits in the wild have been reported.
Potential Impact
An unauthenticated attacker can exploit this vulnerability to inject malicious JavaScript into the web interface of affected IBM DOORS products. This can lead to altered web UI behavior and potential disclosure of user credentials within a trusted session. The impact affects confidentiality and integrity but does not affect availability. The vulnerability could facilitate further attacks if exploited.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is released, users should apply any recommended workarounds or mitigations provided by IBM. Monitor IBM's security advisories for updates and consider restricting access to the affected web interfaces to trusted users only.
CVE-2025-0152: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in IBM Engineering Requirements Management DOORS and DOORS Web Access
Description
IBM Engineering Requirements Management DOORS and DOORS Web Access 9.7.2.1 through 9.7.2.11, and 9.6.1.1 through 9.6.1.13 is vulnerable to cross-site scripting. This vulnerability allows an unauthenticated attacker to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session.
CVSS v3.1
Score 6.1medium
Affected software
cpe:2.3:a:ibm:engineering_requirements_management_doors_and_doors_web_access:9.7.2.1:*:*:*:*:*:*:*cpe:2.3:a:ibm:engineering_requirements_management_doors_and_doors_web_access:9.7.2.11:*:*:*:*:*:*:*cpe:2.3:a:ibm:engineering_requirements_management_doors_and_doors_web_access:9.6.1.1:*:*:*:*:*:*:*cpe:2.3:a:ibm:engineering_requirements_management_doors_and_doors_web_access:9.6.1.13:*:*:*:*:*:*:*Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2025-0152 is a cross-site scripting vulnerability (CWE-79) affecting IBM Engineering Requirements Management DOORS and DOORS Web Access versions 9.7.2.1 through 9.7.2.11 and 9.6.1.1 through 9.6.1.13. The vulnerability enables unauthenticated attackers to embed arbitrary JavaScript code in the web UI, which can alter intended functionality and potentially disclose credentials within a trusted session. The CVSS 3.1 base score is 6.1, reflecting network attack vector, low attack complexity, no privileges required, user interaction required, scope change, and low impact on confidentiality and integrity with no impact on availability. No vendor advisory or patch information is currently available, and no known exploits in the wild have been reported.
Potential Impact
An unauthenticated attacker can exploit this vulnerability to inject malicious JavaScript into the web interface of affected IBM DOORS products. This can lead to altered web UI behavior and potential disclosure of user credentials within a trusted session. The impact affects confidentiality and integrity but does not affect availability. The vulnerability could facilitate further attacks if exploited.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is released, users should apply any recommended workarounds or mitigations provided by IBM. Monitor IBM's security advisories for updates and consider restricting access to the affected web interfaces to trusted users only.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- ibm
- Date Reserved
- 2024-12-31T19:08:58.246Z
- Cvss Version
- 3.1
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a6b88839c2644c7f86a7f17
Added to database: 07/30/2026, 17:23:15 UTC
Last enriched: 07/30/2026, 17:38:11 UTC
Last updated: 07/31/2026, 00:40:20 UTC
Views: 7
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.