CVE-2025-0976: CWE-532 Insertion of Sensitive Information into Log File in Hitachi Hitachi Ops Center API Configuration Manager

0
Medium
VulnerabilityCVE-2025-0976cvecve-2025-0976cwe-532
Published: Wed Feb 25 2026 (02/25/2026, 04:17:58 UTC)
Source: CVE Database V5
Vendor/Project: Hitachi
Product: Hitachi Ops Center API Configuration Manager

Description

CVE-2025-0976 is an information exposure vulnerability in Hitachi Ops Center API Configuration Manager and Hitachi Configuration Manager. It involves the insertion of sensitive information into log files, potentially exposing confidential data. The vulnerability affects versions from 10. 0. 0-00 up to but not including 11. 0. 4-00 for Ops Center API Configuration Manager, and 8. 6. 1-00 up to but not including 11. 0.

AI-Powered Analysis

AILast updated: 02/25/2026, 05:12:00 UTC

Technical Analysis

CVE-2025-0976 is classified under CWE-532, which pertains to the insertion of sensitive information into log files, leading to unintended information disclosure. This vulnerability affects Hitachi Ops Center API Configuration Manager versions 10.0.0-00 through 11.0.3-00 and Hitachi Configuration Manager versions 8.6.1-00 through 11.0.4-00. The issue arises when sensitive data such as credentials, tokens, or configuration secrets are logged in plaintext or insufficiently protected formats within system logs. Attackers with local access and low privileges can access these logs to extract confidential information, potentially facilitating further attacks or unauthorized access. The vulnerability does not require user interaction but does require authentication with low privileges, and the attack vector is local (AV:L). The impact is high on confidentiality, with no impact on integrity or availability. The vulnerability has a CVSS v3.1 score of 4.7, reflecting a medium severity level. No patches were linked at the time of reporting, and no exploits are known to be active in the wild. This vulnerability highlights the importance of secure logging practices and proper handling of sensitive information within enterprise management tools.

Potential Impact

The primary impact of CVE-2025-0976 is the exposure of sensitive information through log files, which can lead to confidentiality breaches. Organizations using affected Hitachi management products risk unauthorized disclosure of credentials, tokens, or configuration details if an attacker gains local access. This exposure can facilitate privilege escalation, lateral movement, or further compromise of enterprise infrastructure. Although the vulnerability requires local access and low privileges, it can be exploited by malicious insiders or attackers who have already gained limited footholds. The lack of impact on integrity and availability limits the scope of damage, but confidentiality breaches can still result in significant operational and reputational harm. Enterprises relying on these Hitachi products for storage and configuration management, especially in regulated industries, may face compliance risks and increased attack surface due to this vulnerability.

Mitigation Recommendations

To mitigate CVE-2025-0976, organizations should first restrict local access to systems running affected Hitachi Ops Center API Configuration Manager and Configuration Manager to trusted personnel only. Implement strict access controls and monitoring on log files to detect unauthorized access attempts. Review and sanitize logging configurations to ensure sensitive information is not recorded in plaintext or at all. Employ log management solutions that support encryption and access auditing. Apply vendor patches or updates as soon as they become available to address this vulnerability. If patches are not yet released, consider temporary workarounds such as disabling verbose logging or redirecting logs to secure storage with limited access. Conduct regular audits of logs to identify any sensitive data exposure and remove or redact such information. Additionally, educate administrators about the risks of sensitive data in logs and enforce least privilege principles to minimize the risk of exploitation.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.2
Assigner Short Name
Hitachi
Date Reserved
2025-02-03T05:28:11.381Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 699e80ffb7ef31ef0bd6da5d

Added to database: 2/25/2026, 4:56:31 AM

Last enriched: 2/25/2026, 5:12:00 AM

Last updated: 2/25/2026, 10:56:55 AM

Views: 6

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats