Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2025-26411: CWE-434 Unrestricted Upload of File with Dangerous Type in Wattsense Wattsense Bridge

0
High
VulnerabilityCVE-2025-26411cvecve-2025-26411cwe-434
Published: Tue Feb 11 2025 (02/11/2025, 09:21:16 UTC)
Source: CVE Database V5
Vendor/Project: Wattsense
Product: Wattsense Bridge

Description

An authenticated attacker is able to use the Plugin Manager of the web interface of the Wattsense Bridge devices to upload malicious Python files to the device. This enables an attacker to gain remote root access to the device. An attacker needs a valid user account on the Wattsense web interface to be able to conduct this attack. This issue is fixed in recent firmware versions BSP >= 6.1.0.

AI-Powered Analysis

AILast updated: 11/04/2025, 00:07:42 UTC

Technical Analysis

CVE-2025-26411 is a vulnerability classified under CWE-434 (Unrestricted Upload of File with Dangerous Type) affecting Wattsense Bridge devices. The flaw resides in the Plugin Manager component of the device's web interface, which insufficiently validates uploaded files. An attacker with valid user credentials can upload malicious Python scripts, which the device executes, resulting in remote root access. This level of access allows full control over the device, enabling attackers to manipulate device functions, exfiltrate data, or pivot to other network segments. The vulnerability requires authentication but no additional user interaction, making it relatively straightforward for insiders or compromised users to exploit. The issue affects all versions prior to BSP 6.1.0, where the vendor has implemented proper file validation and upload restrictions. The CVSS 3.1 score of 8.8 indicates a high-severity vulnerability with network attack vector, low attack complexity, and high impact on confidentiality, integrity, and availability. Although no public exploits are known, the potential for severe operational disruption and unauthorized control is significant, especially in environments where Wattsense Bridges manage critical building automation or IoT infrastructure.

Potential Impact

For European organizations, this vulnerability poses a serious risk to operational technology and building management systems that rely on Wattsense Bridge devices. Successful exploitation can lead to full device compromise, allowing attackers to disrupt building automation, manipulate environmental controls, or use the device as a foothold for lateral movement within corporate networks. This can result in data breaches, service outages, and safety hazards. The high CVSS score reflects the potential for widespread impact, especially in sectors such as energy management, smart buildings, and industrial IoT deployments prevalent across Europe. Organizations in critical infrastructure sectors may face regulatory and compliance consequences if such vulnerabilities are exploited. The need for authentication limits exposure to some extent, but insider threats or credential compromise remain significant concerns. The absence of known exploits in the wild provides a window for remediation before active exploitation occurs.

Mitigation Recommendations

European organizations should immediately verify the firmware version of all Wattsense Bridge devices and upgrade to BSP 6.1.0 or later to remediate this vulnerability. Access to the Plugin Manager web interface must be restricted using network segmentation, VPNs, or firewall rules to limit exposure to authorized personnel only. Implement strong authentication mechanisms, including multi-factor authentication (MFA), to reduce the risk of credential compromise. Regularly audit user accounts and permissions to ensure only necessary users have access to the device management interface. Monitor logs for unusual upload activities or unauthorized access attempts. Employ network intrusion detection systems (NIDS) to detect anomalous behavior indicative of exploitation attempts. Additionally, consider isolating building automation networks from corporate IT networks to contain potential breaches. Establish incident response plans specific to IoT and building management systems to quickly address any detected compromise.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.2
Assigner Short Name
SEC-VLab
Date Reserved
2025-02-10T07:48:38.352Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 69091e18c28fd46ded869883

Added to database: 11/3/2025, 9:26:48 PM

Last enriched: 11/4/2025, 12:07:42 AM

Last updated: 12/20/2025, 12:26:14 PM

Views: 37

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats