Skip to main content
VulnerabilityPublished

CVE-2025-27028: Radiflow iSAP Smart Collector · Incorrect Privilege Assignment

Affects Radiflow iSAP Smart CollectorSource CVE Database V5

0

Not known to be exploited · CVSS 6.8 Medium.

Data as of 26 Oct 2026, 17:16 UTC

CVSS 3.1 base score
6.8Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.3% chance of exploitation in 30 days – higher than 23% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 9 Jul 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

Affected software

ProductAffectedFixed in
Centoscentos/iSAP-Smart-Collectorpkg:rpm/centos/iSAP-Smart-CollectorOther threatsAffected
  • =1.20
Fixed in–

Check your own hosts for these packages with threat-finder (opens in a new tab), our free open-source scanner.

AI-suggested

  1. Restrict access to the 'vpuser' account to only trusted administrators and monitor its usage closely.
  2. Implement strict access controls and audit logging on the iSAP Smart Collector systems to detect any unauthorized file access attempts.
  3. Employ file integrity monitoring solutions to alert on unusual read operations on sensitive files such as /etc/shadow or other critical system files.
  4. Network segmentation should be enforced to limit exposure of the iSAP Smart Collector devices to only necessary management networks.
  5. Apply principle of least privilege rigorously by reviewing and hardening user permissions on the affected systems.
  6. Engage with Radiflow for patches or updates addressing this vulnerability and plan for timely deployment once available.
  7. Consider deploying host-based intrusion detection systems (HIDS) to detect anomalous behavior related to file access by the 'vpuser' or other accounts.
  8. Conduct regular security assessments and penetration tests focusing on privilege escalation vectors within the environment. These steps go beyond generic advice by focusing on monitoring, access control, and network segmentation tailored to the specific vulnerability context.

Description

The Linux deprivileged user vpuser in Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) can read the entire file system content, including files belonging to other users and having restricted access (like, for example, the root password hash).