CVE-2025-48022: Yokogawa Electric Vnet/IP Interface Package · CWE-130
Affects Yokogawa Electric Vnet/IP Interface PackageSource CVE Database V5
Not known to be exploited · CVSS 6.0 Medium.
Data as of 25 Oct 2026, 19:02 UTC
- EPSS
- 0.1% chance of exploitation in 30 days – higher than 8% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:NExploitation evidence
Disclosed: evidence found.
CVE published 13 Feb 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-25.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| Yokogawa Electric CorporationVnet/IP Interface Package | Affected
| Fixed in– |
AI-suggested
Organizations should implement the following specific mitigation strategies: 1) Apply patches or updates from Yokogawa Electric Corporation as soon as they become available to address this vulnerability directly. 2) Enforce strict network segmentation to isolate Vnet/IP interfaces from general enterprise networks and untrusted zones, limiting attacker access to adjacent networks only. 3) Deploy intrusion detection and prevention systems (IDS/IPS) with signatures or anomaly detection tuned to identify malformed or suspicious Vnet/IP packets. 4) Monitor network traffic for unusual patterns or repeated connection attempts to the Vnet/IP interface, enabling early detection of exploitation attempts. 5) Restrict physical and logical access to industrial control networks, ensuring only authorized personnel and systems can communicate with the Vnet/IP components. 6) Conduct regular security assessments and penetration testing focused on ICS network boundaries to identify and remediate exposure points. 7) Develop and test incident response plans specifically for denial of service scenarios affecting industrial control communications. These measures go beyond generic advice by focusing on network architecture, monitoring, and operational readiness tailored to the industrial environment.
Description
A vulnerability has been found in Vnet/IP Interface Package provided by Yokogawa Electric Corporation. If affected product receives maliciously crafted packets, Vnet/IP software stack process may be terminated. The affected products and versions are as follows: Vnet/IP Interface Package (for CENTUM VP R6 VP6C3300, CENTUM VP R7 VP7C3300) R1.07.00 or earlier