Skip to main content
VulnerabilityPublished

CVE-2026-116781: signalwire freeswitch · Off-by-one Error

Affects signalwire freeswitchSource CVE Database V5

0
Compare

Not known to be exploited · CVSS 5.3 Medium : upgrade to 1.11.2 when convenient.

Data as of 5 Nov 2026, 19:51 UTC

CVSS 3.1 base score
5.3Medium
How severe the flaw is on the 0–10 CVSS scale.

Thin evidence

One scorer or none
CVSS scores by source
CNA (GitHub_M)CVSS 3.15.3
Patch
Available – fixed in 1.11.2
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 5 Nov 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 5 Nov 2026.

What to do

Upgrade signalwire freeswitch to 1.11.2.

Affected software

ProductAffectedFixed in
signalwirefreeswitchAffected
  • <1.11.2
Fixed in
  • 1.11.2

AI-suggested

Upgrade FreeSWITCH to version 1.11.2 or later, where this off-by-one error has been fixed. The vulnerability is only exploitable if mod_xml_rpc and its WebSocket endpoint are enabled, which are disabled by default. If these features are not in use, the risk is reduced. No additional mitigation is required beyond applying the official fix.

Description

CVE-2026-116781 is an off-by-one error vulnerability in FreeSWITCH prior to version 1.11.2. The flaw occurs in the ws_read_frame() function when unmasking WebSocket payloads, potentially causing writes up to 14 bytes beyond the receive buffer and a terminating NUL byte one byte out of bounds. This vulnerability is reachable before authentication if mod_xml_rpc and its WebSocket endpoint are enabled, though these features are disabled by default. The out-of-bounds writes remain within the same connection handle's adjacent outbound buffer, and no process crash or cross-session data disclosure has been demonstrated. The issue is fixed in FreeSWITCH version 1.11.2.

References

Community reviews