CVE-2026-11739: NETGEAR MR60 · OS Command Injection
Affects NETGEAR MR60Source CVE Database V5
Not known to be exploited · CVSS 4.9 Medium : upgrade to V1.1.8.142 when convenient.
Data as of 10 Nov 2026, 23:24 UTC
- EPSS
- 2.5% chance of exploitation in 30 days – higher than 85% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- Patch
- Available – fixed in V1.1.8.142, V1.0.4.48, V1.0.2.46 +6
CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U/AU:N/R:U/V:D/RE:L/U:AmberExploitation evidence
Disclosed: evidence found.
CVE published 11 Aug 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 10 Nov 2026.
What to do
Upgrade to a fixed release listed under Affected software.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| NETGEARMR60 | Affected
| Fixed in
|
| NETGEARMR70 | Affected
| Fixed in
|
| NETGEARMR90 | Affected
| Fixed in
|
| NETGEARMS60 | Affected
| Fixed in
|
| NETGEARMS70 | Affected
| Fixed in
|
| NETGEARMS90 | Affected
| Fixed in
|
AI-suggested
If you cannot patch yet, network administrators should limit exposure of the device to untrusted local network users and monitor for suspicious network activity. No official mitigation or temporary fix is currently documented by NETGEAR.
Description
A command injection vulnerability in certain affected NETGEAR Nighthawk devices allows a network-adjacent attacker with the ability to intercept and modify local network traffic (attacker in the middle) to compromise the confidentiality and integrity of the affected device.
References
- netgear.com/support/product/mr60/ (opens in a new tab)
- netgear.com/support/product/mr70/ (opens in a new tab)
- netgear.com/support/product/ms90/ (opens in a new tab)
- netgear.com/support/product/mr90/ (opens in a new tab)
- netgear.com/support/product/rax20/ (opens in a new tab)
- netgear.com/support/product/rax35/ (opens in a new tab)
- netgear.com/support/product/rax200/ (opens in a new tab)
- netgear.com/support/product/ms60/ (opens in a new tab)
- netgear.com/support/product/rax41/ (opens in a new tab)
- netgear.com/support/product/ms70/ (opens in a new tab)
- netgear.com/support/product/rax41v2/ (opens in a new tab)
- netgear.com/support/product/rax35v2/ (opens in a new tab)
- netgear.com/support/product/rax42/ (opens in a new tab)
- netgear.com/support/product/rax42v2/ (opens in a new tab)
- netgear.com/support/product/rax43/ (opens in a new tab)
- netgear.com/support/product/rax49s/ (opens in a new tab)
- netgear.com/support/product/rax50/ (opens in a new tab)
- netgear.com/support/product/rax43v2/ (opens in a new tab)
- netgear.com/support/product/rax50v2/ (opens in a new tab)
- netgear.com/support/product/rax45/ (opens in a new tab)
- netgear.com/support/product/raxe500/ (opens in a new tab)
- netgear.com/support/product/rax80/ (opens in a new tab)
- netgear.com/support/product/xr1000/ (opens in a new tab)
- netgear.com/support/product/rs700/ (opens in a new tab)
- netgear.com/support/product/xr1000v2/ (opens in a new tab)
- kb.netgear.com/000070887/August-2026-NETGEAR-Security-Advisory (opens in a new tab)